Prepare for operation
Greenstar 4000 – 6 720 891 170 (2020/09)
8
3.2 Topping up the system pressure
Your installer should have informed you where to find the filling system
and instructed you in its use.
NOTICE
System fill method
You must remove the “filling key” or disconnect the external filling
loop after re-pressurisation, to comply with the Water Authority
regulations.
To aid in filling the system.
Ensure the Central Heating is on.
(optional accessory)
Automatic filling facility
The automatic filling device refills the water into the heating system as
required. Your installer programmes the filling device according to your
heating system. Have your installer explain the function of the automatic
filling device to you.
Automatic refilling keeps the pressure in the heating system at the
programmed value.
Fig. 4 Automatic filling facility
Removal and replacement of bottom panel
To gain access to the filling link, remove the bottom panel.
Press in the tabs [A] and pull the bottom panel down to remove.
Fig. 5 Bottom panel
To replace the bottom panel, ensure that the tabs [B] line up with the
edges of the boiler [C] and push into place until the tabs [A] click into
place.
(optional accessory)
Keyless filling link
Locate the filling link (underneath the appliance on the right hand side)
and follow the instructions for re-pressurising the system.
Re-pressurise the system.
To start the filling process, pull the lever [1] down.
The pressure menu indicator moves, the displayed message may
change.
To stop the filling process, Release the lever [1] when the:
Pressure menu [2] indicates the pressure is ok and the pressure
menu indicator is in the green zone.
Top up the system pressure, if as a result of the air bleeding, the
pressure drops off.
Fig. 6 Keyless filling link
(optional accessory)
Keyed filling link
Remove the bottom panel to locate the filling key and filling link
(underneath the appliance on the right hand side), follow the
instructions for re-pressurising the system.
Refer to figure 7.
Locating the filling key into position.
Push the filling key [3] firmly into the body of the filling link,
ensuring the arrow [4] on the key shaft lines up with the open
padlock [1] symbol.
Turn the filling key [3] to the right, to the stop, ensure the key is
locked and that it cannot still turn. The arrow [4] should line up
with the closed padlock [2] symbol.
Re-pressurise the system.
Do not over-tighten the white knob [6] when closing.
To start the filling process, turn the white knob [6] to the left.
The pressure menu indicator moves and the displayed message
may change [5].
To stop the filling process, turn the white knob [6] to the right to close
the valve when:
The pressure menu reads OK and the pressure menu indicator is
in the green zone [7].
Top up the system pressure, if as a result of the air bleeding, the
pressure drops off.
Once the pressure has settled between 0.8 and 1.7 bar.
Ensure the valve is closed.
Remove the filling key.
Turn the filling key [3] to the left, to the stop, so that the arrow {4]
lines up with the open padlock symbol [1].
Pull the key straight down to remove. Please remember to store
the key in a safe place.
0010023397-001
A
B
B
CC
0010036333-001
0010022968-001
11
2
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch Greenstar 4000 - GR4700i Combi at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch Greenstar 4000 - GR4700i Combi in the language / languages: English as an attachment in your email.

The manual is 4.46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info