Prepare for operation
7
Greenstar 4000 – 6 720 891 170 (2020/09)
3 Prepare for operation
3.1 Sealed heating system
Appliances that can be connected to sealed heating systems are pre-
pressurised before operation, this pressure must be maintained for safe
use of the appliance.
Check regularly that the pressure is maintained.
Re-charge the system if the pressure indicator reads less than 0.8
bar.
If a permanent significant decrease or increase in pressure is shown
on the pressure indicator, contact your installer or maintenance
engineer.
Pressure indicator
Type of pressure indicator for the system pressure.
– Pressure gauge (an analogue dial showing the pressure)
– Pressure menu (a digital readout of the pressure)
Your appliance may have one or both types of methods to indicate the
system pressure. The type of method used on this appliance will be
detailed in the following section.
3.1.1 Checking the system pressure
The appliance pressure menu indicates the pressure within the heating
system during standby and operating periods.
Your installer will advise you of the optimum operating pressure.
Check the system pressure on the pressure menu.
Static pressure is when appliance is cold and has not fired for
heating or hot water. This will generally be 0.8 - 1.7 bar.
Operating pressure is when the appliance is firing for a heating
or hot water demand. This will generally be 1 - 2 bar.
Fig. 2 Checking the operating pressure
[1] Static pressure range.
[2] Operating pressure range.
[3] Pressure menu indicator.
The pressure menu can be accessed via the Boiler status screen.
Press the menu key ( ). Select and confirm Boiler status.
The screen Boiler status with a pressure menu indicator appears.
Check the system pressure on the display.
Indicator in red zone: pressure is too low or too high.
Indicator in yellow zone: pressure is low or slightly too high.
Indicator in green zone: pressure is normal.
Top up the heating water, if the pressure is low or too low.
3.1.2 Low pressure indication
Low pressure (shaded area [A]) will be indicated on the appliance:
The pressure indicator is within the area between 0 and 0.79 bar in
the pressure menu display (left hand yellow and red zone).
Additionally there is a message displayed.
Fig. 3 Low pressure indication
[A] Low pressure area
3.1.3 Constantly re-pressurising the system
Constantly having to re-pressurise the heating system should be
investigated as it is an indicator of potential leaks and the concentration
of inhibitor protection in the system will be reduced; this can result in
corrosion within the heating system, reducing efficiency and increasing
contaminates.
Check for leaks on heating system (pipework and radiator valves).
Contact your installer or maintenance engineer if a recurring
significant decrease or increase in pressure is indicated on the
pressure screen.
System pressure increasing:
If the system pressure repeatedly increases and you need to vent air
from the radiators, refer to section 8.3 "System gassing
troubleshooting", page 17.
Min Max
0010033762-001
3
1 2
0010033766-001
Fault - 1017
Pressure: 0.2 bar
System pressure
too low
A
Max
Min
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch Greenstar 4000 - GR4700i Combi at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch Greenstar 4000 - GR4700i Combi in the language / languages: English as an attachment in your email.

The manual is 4.46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info