697434
57
Zoom out
Zoom in
Previous page
1/72
Next page
Display information
6720813171 (2016/05) 57
e
[6/a/\|
e
[2/2/7|
e
Fault:
The system has detected an insufficient ionisation current
after four start-up attempts.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[6/c/\|
e
[2/2/8|
e
Fault:
The system has detected an ionisation current before
burner start-up.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[6/c/\|
e
[3/0/6|
e
Fault:
An ionisation current has been measured after the burner
shut down.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[6/l/\|
e
[2/2/9|
e
Fault:
The system has detected an insufficient ionisation current
during the operating phase.
No
4)
5)
Off
e
[6/p/\|
e
[2/6/9|
e
Fault:
The glow ignitor was activated for more than 10 minutes.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[6/y/\|
e
[2/0/3|
e
Fault:
The ionisation current is too high.
Yes flashing
1Hz
No heating operation and no
DHW.
e
[7/c/\|
e
[2/3/1|
e
Fault:
The power supply was interrupted during a locking fault
4A, 4C, 4E, 4F, 4L, 4P, 4U, 4Y.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[7/l/\|
e
[2/6/1|
e
Fault:
The UBA 3 is defect.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[7/l/\|
e
[2/8/0|
e
Fault:
The UBA 3 is defect.
Yes
5)
6)
7)
8)
flashing
1Hz
e
[8/y/\|
e
[2/3/2|
2)
Operating phase:
The external switch contact is open.
Off No heating operation and no
DHW.
[8/8/8| Start-up phase:
The boiler starts up after activation of the mains power
supply or completion of a system reset. This code is
displayed for a maximum of 4 minutes.
On
e
[9/a/\|
e
[2/3/5|
e
Fault:
The UBA 3 or the KIM is defective.
Yes flashing
1Hz
No heating operation and no
DHW.
e
[9/h/\|
e
[2/3/7|
e
Fault:
The UBA 3 or the KIM is defective.
Yes flashing
1Hz
No heating operation and no
DHW.
e
[9/h/\|
e
[2/6/7|
e
Fault:
The UBA 3 or the KIM is defective.
Yes flashing
1Hz
No heating operation and no
DHW.
e
[9/h/\|
e
[2/7/2|
e
Fault:
The UBA 3 or the KIM is defective.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[9/l/\|
e
[2/3/4|
e
Fault:
The contacts for the gas valve have been broken.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[9/l/\|
e
[2/3/8|
e
Fault:
The UBA 3 or the KIM is defective.
Yes
5)
6)
7)
8)
flashing
1Hz
e
[9/p/\|
e
[2/3/9|
e
Fault:
The UBA 3 or the KIM is defective.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
Display codes
Display code
LED on
UBA 3 Other effectsz
Main
display
code
z
Sub
display
code
z Key to display code
Reset
requi-
red?
Table 24 Display codes
57


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch GB162-80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch GB162-80 in the language / languages: English as an attachment in your email.

The manual is 5,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Worcester-Bosch GB162-80

Worcester-Bosch GB162-80 Installation Guide - English - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info