697434
24
Zoom out
Zoom in
Previous page
1/72
Next page
Installation
6720813171 (2016/05)24
Example of a flue design calculation for concentric flue system
100/150 using length method
Boiler: GB162-80
Flue system: concentric 100/150
Maximum length: 18 m.
Here we have:
4 meter pipe (2 x 2 m)4.0 m
2 x 90° bends (2 x 2.1 m)4.2 m
The total length of this flue system =8.2 m
Sum of length (8.2 m) < maximum length (18 m) robust flue design!
Fig. 36 Example 1
8.5 Electrical connections
When connecting the electrical components, observe the wiring
diagram, the installation and servicing instructions of the relevant
product.
6 720 648 726-036.1TD
Pipe=2m
Pipe=2m
Roofterminal
90° bend
Length=21m
90° bend
Length=21m
Maximum length
allowed after the
boiler (GB162-80)
18 m
WARNING: Damage to the installation due to short
circuits.
To prevent electrical components from short-circuiting,
only use:
original cables and wiring supplied by the
manufacturer.
single core cable.
Use cable of at least 0.75 mm².
If the mains lead has to be replaced, you may only use
an original manufacturer-supplied mains lead.
DANGER: Danger of fatal accident due to electric
current when the boiler is open.
Before opening the boiler: Isolate the mains supply.
Secure the heating system so that it cannot be
switched on again unexpectedly, pulling the mains
plug from the wall socket.
The 230V converter can only be used for the
GB162-50/65 appliance.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester-Bosch GB162-80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester-Bosch GB162-80 in the language / languages: English as an attachment in your email.

The manual is 5,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Worcester-Bosch GB162-80

Worcester-Bosch GB162-80 Installation Guide - English - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info