9. The exhaust duct should be as short and straight as possible. The diameter of the
exhaust hose should be at least 120/150 mm (look at chapter TECHNICAL DATA).
Otherwise you have to expect increased noise and decreased performance of your
appliance.
10. The proper maximum bending angle outwards is 120
0
.
11. Use smooth tubes or flexible, non-inflammable exhaust hoses only.
12. When the exhaust duct is connected horizontally, a minimum falling gradient of
1 cm/m or an inclination of 2
0
is required. Otherwise condensate will get into the
motor of the hood.
13. When an exhaust duct is used, the ending of the exhaust hose must be adjusted
into the direction of flow.
14. If the exhaust duct passes through cool areas (e.g. an attic), a temperature gradient
may occur in the different parts of the exhaust duct so condensate will be
generated. Proper insulation of the corresponding parts of the exhaust duct will
then be needed. Equip such an exhaust duct with a condensate trap if need be.
15. Depending on the model the hood is equipped with one (top) or two (top,
back) outlets.
16. The idle outlet is covered by a plastic cap. You can remove this cap by turning it
anticlockwise. Use the cap to cover the idle outlet.
2.1 Minimum distances
Strictly observe the minimum distance between hood and hob.
It is also absolutely necessary to observe the individual minimum
distances to extractor hoods which are specified in the instruction manual
of your hob / oven / etc.
REQUIRED MINIMUM DISTANCE HOOD TO
Ceramic-glass rings / hotplates
min. 65 cm
Gas cooker
min. 75 cm
Coal / oil / stove wood firing
min. 85 cm
1. The minimum distances do not represent the required total height but a minimum
value generated by adding the height of the hob (floor ↔ hob) and the required
minimum distance of the hob to the extractor hood (hob ↔ extractor hood)
(floor ↔ hob)
+
(hob ↔ extractor hood)
=
MINIMUM INSTALLATION HEIGHT
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wolkenstein W I4-90A IXTZ at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wolkenstein W I4-90A IXTZ in the language / languages: English, German as an attachment in your email.

The manual is 1,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info