813077
20
Zoom out
Zoom in
Previous page
1/83
Next page
Bedienungsanleitung Steuerung S4_2006_09_25-neu.doc Page 20 / 83
© wodtke GmbH Tübingen. All rights reserved. Subject to change without notice. Month of issue xx/2007 Art. No. 950 281
5.10 Automatic operation “TW OFF” (only for Waterplus appliances)
Functional message: “TW OFF”
= appliance has been switched off via internal boiler sensor
= appliance has to be switched on manually via I/O key
= functional values can be called up via the “Menu” key
This function is only available with Waterplus appliances. “TW OFF”
means that the appliance is responding to a signal from the internal boiler
sensor inside the heat exchanger (temperature TW). The appliance has
been switched off via this sensor because the desired temperature in the
water heat exchanger has been exceeded. It will be
automatically switched on again later.
Note: If the appliance is now switched off via the I/O
key or through a class 1 error, it can no longer
respond to the external controller and will not start up
automatically again. Instead the display shows “G
OFF” and eventually the “stand-by dot” or, in the
event of an error, the “stand-by dot” flashing
alternately with the error code.
Tip: Do not switch the appliance off via the I/O
key when in the “TW OFF” state. The I/O key is
only intended for manual operation or as an
emergency switch in the event of errors.
5.10.1 Switching on and off via “TW OFF”
When the Waterplus appliance is switched off by an internal
controller after being in operation this is indicated by the messages
“G OFF” and “HE OFF” flashing alternately until the end of fan after-
run time. After this the display shows “TW OFF” alone.
When the appliance is restarted via an internal controller the display
shows “ON” and then for a few seconds the installed programme
version. If all is in order the appliance then enters preheating
programme “Aand eventually heating programme “H”.
5.11 Preheating programme “A”
= display shows “Afor preheating programme
= display shows flashing dot for feed screw operation
= display shows remaining minutes of preheating programme
In the preheating programme the ignition element is active for the
first 10 minutes after starting up, the pellets light after a few minutes
and the appliance runs to operating temperature. The air flow sensors
only become active after one minute, when the fan has reached
constant speed and an air flow has developed. You can adjust thermal
output in steps of 0.5 kW using the +/- keys. Thermal output setting only
becomes active on completion of the preheating programme when the
display changes to “H”. The appliance can also be switched off with the
I/O key during the preheating programme. It then enters the “G OFF”
state and eventually goes into stand-by.
Automatic operation no
longer possible because
appliance has been
switched to “stand-by”.
TW
OFF
G
OFF
.
OFF
TW
OFF
G
OFF
TW
OFF
wodtke
A .
- 15
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wodtke Frank Airplus S4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wodtke Frank Airplus S4 in the language / languages: English as an attachment in your email.

The manual is 3.18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wodtke Frank Airplus S4

Wodtke Frank Airplus S4 User Manual - German - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info