5.9 Automatic operation “HE OFF”
Functional message: “HE OFF”
= appliance switched off via external controller
= appliance must be switched on again manually via I/O key
= functional values can be called u via the “Menu” key
When it displays this message the appliance is responding to an external
controller. The appliance has been switched off via an external controller
and will automatically be switched on again later by the same controller.
Note: If the appliance is now switched off via the I/O
key or through a class 1 error, it can no longer
respond to the external controller and will not start up
automatically again. Instead the display shows “G
OFF” and eventually the “stand-by dot” or, in the
event of an error, the “stand-by dot” flashing
alternately with the error code.
Tip: Do not switch the appliance off via the I/O key when
using an external controller. The I/O key is only intended
for manual operation or as an emergency switch in the
event of errors.
Note:
When the pellet stove is being controlled externally, for ex. via a heating controller, it is
advisable to clean the burner pot and its holes (combustion air holes) at least once a day and at
the same time check that the burner pot is securely seated (see Chapter 0).
5.9.1 Switching the appliance on via an external controller
The appliance starts up as soon as its “ON/OFF” input receives an
“ON” signal from an external controller. After this the display briefly
shows “ON” and then, for a few seconds, the programme version
installed, for ex. “P3 400”. During these seconds the system checks
whether all functions are o.k. In the event of an error the appliance
does not start and instead display the relevant error message (see
Chapter 0 ff.). If everything is in order the appliance then enters
preheating programme “A” and eventually heating programme
“H”.
Thermal output can also be adjusted in automatic operating mode
by simply pressing the “+” and “-” keys.
With a suitable controller you can also modulate thermal output automatically rather than
adjusting it manually (see ### Modulation via external controller).
5.9.2 Switching the appliance off via an external controller
When the appliance is switched off by an external controller after
being in operation this is indicated by the messages “G OFF” and
“HE OFF” flashing alternately until the end of fan after-run time.
After this the display shows “HE OFF” alone.
G
OFF
.
OFF
Appliance has been
switched to stand-by” and
can no longer respond to
an external controller
HE
OFF
wodtke
ON
P3
400
A
-15
This appears for a few
seconds (functional check).
G
OFF
HE
OFF
HE
OFF
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wodtke Frank Airplus S4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wodtke Frank Airplus S4 in the language / languages: English as an attachment in your email.

The manual is 3.18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wodtke Frank Airplus S4

Wodtke Frank Airplus S4 User Manual - German - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info