8.3.1 "On / Off" (Eigang EIN/AUS) Input -
Display Indicator HE ON / HE OFF
24 V digital input (bridged, protected against po-
larity reversal): for activation / deactivation via an
external, potential-free room thermostat or heating
controller.
Fig. 34: on/off input
Bridge closed = furnace ON
Bridge open = furnace OFF
Note: Button on the control board has prior-
ity over the "On/Off" input.
8.3.2 "Modulation" Input (Eingang
Modul.) Display Indicator HE
Analogue input, 0-10 V or 4-20 mA switchable (not
bridged, note polarity): for modulation of the fur-
nace output via an external modulating room ther-
mostat or heating controller. The "Modulation" in-
put must first be switched active for use. The
"Modulation" input only responds if the furnace is
activated; that is, a combination with the
"ON/OFF" input is required.
Fig. 35: modulation input
1. Attention:
Note polarity
2. DIP switches: V / mA changeover for "Modula-
tion" input
Priorities:
I/O button has first priority, MIN/MAX (external),
ON/OFF (external), R.M (internal) have priority
over modulation.
If the modulation input is switched active, the fur-
nace no longer responds to the RS 485 interface
(BUS is automatically deactivated as soon as
modulation is activated) or to modulation
mode/time switch mode via BB-S5 (TC1). Notice:
a corresponding controller must be connected to
the modulation input after activation, because oth-
erwise the furnace will run permanently only at the
smallest load.
Activation of the modulation input: Only permitted
for specialist companies! Proceed as follows:
Press button 1 x change to menu level 1
Now hold + + buttons simultane-
ously for at least 3 seconds until "S" appears in
the display change to menu level 2
Now hold or buttons pressed until "M
OFF" indicator appears in the display.
Now press + buttons simultaneously
until "M ON" indicator appears in the display
the "Modulation" input is now switched active.
Press button for at least 3 seconds return
to operating level
Switch over modulation input from 0-10 V to 4-20
mA:
Fig. 36: modulation DIP switches
0-10 V = both DIP switches to V to the
right;
4-20 mA = both DIP switches to mA to the
left
1
2
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wodtke Easy.nrg S5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wodtke Easy.nrg S5 in the language / languages: English as an attachment in your email.

The manual is 6.01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Wodtke Easy.nrg S5

Wodtke Easy.nrg S5 User Manual - German - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info