3
Installation must be carried out by a qualified electrician
who is fully aware of current safety and installation
regulations. The manufacturer declines all liability for injury
to persons or animals and for damage to property resulting
from failure to observe the regulations provided in this
chapter.
Electrical connections
Hob electrical connection must be made before
connecting the appliance to the electricity supply.
Electrical connection must be carried out in compliance
with the regulations of the local electric utility company.
Make sure that the voltage indicated on the rating plate
on the underside of the appliance corresponds to the
domestic power supply voltage.
Regulations require that the appliance is earthed: use
conductors (including the earth conductor) of the
appropriate size only.
For electrical connection, use an H05 RR-F type cable as
specified in the table “Power supply voltage”.
The power supply cable must be long enough
to allow the hob to be removed from the
worktop and must be positioned so as to avoid
damage or overheating caused by contact with
the base of the hob itself. Do not use extension leads.
Power supply voltage
If the hob already has a power cable, follow the
instructions given on the label attached to the
cable.
Connect the appliance to the electricity supply by
means of an all-pole disconnect switch with minimum
contact gap of 3 mm.
Connecting to the terminal board
Connect the yellow/green earth wire to the terminal with
the symbol . This wire must be longer than the other
wires.
1. Remove the terminal block cover (A), undoing the
screw and inserting the cover in the terminal block
hinge (B).
2. Strip approx. 70 mm of sheath from the power supply
cable.
3. Strip approx. 10 mm of sheath from the wires. Insert
the power supply cable into the cable clamp and
connect the wires to the terminal board as indicated in
the diagram next to the terminal board itself.
4. Secure the power cable with the cable clamp.
5. Close the cover (C) and screw it on the terminal block
with the removed screw - point (1).
Each time the cooktop is connected to the mains it
carries out an automatic check which lasts several
seconds.
INSTALLATION and ELECTRICAL CONNECTION
Wires Amount x size
230V ~ +
3 X 4 mm
2
230-240V ~ +
3 X 4 mm
2
(Australia only)
230V 3 ~ +
4 X 1.5 mm
2
400V 3N ~ +
5 X 1.5 mm
2
400V 2N ~ +
4 x 1.5 mm
2
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
230V
A
B
C
400V 3N ~ 230V ~
230-240V~FOR AU ONLY
230V~FOR UK ONLY
400V 2N ~
230V 3~
ONLY FOR BELGIUM
400V 2N~
FOR NL ONLY
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Whirlpool ACM 702 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Whirlpool ACM 702 in the language / languages: English as an attachment in your email.

The manual is 1,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Whirlpool ACM 702

Whirlpool ACM 702 User Manual - German - 8 pages

Whirlpool ACM 702 User Manual - Dutch - 7 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info