WESTFIRE · WF36 WF37
10
UK
UNIQ 36 and UNIQ36 PEDESTAL dimensions / UNIQ37 and UNIQ37 PEDESTAL dimensions
Stove model Weight Nominal heat output
Wood Smokeless fuels
UNIQ36 / UNIQ37 90 kg 7.2 KW N/A
UNIQ36 Pedestal /UNIQ37 Pedestal 95 kg 7.2 KW N/A
UNIQ37 Large 100 kg 7.2 KW N/A
UNIQ36 / UNIQ37 UNIQ36 Pedestal / UNIQ37 Pedestal UNIQ37 Large
Height 980 mm Pedestal 1: 1150 mm / Pedestal 2: 1070 mm 1310 mm
Width 505 mm 505 mm 505 mm
Depth 445 mm 445 mm 445 mm
Closed combustion option Order specific closed combustion option
STOVE PERFORMANCE & TESTING
Westfire UNIQ36/ WF36 Pedestal and UNIQ37/ WF37 Pedestal have been approved in accordance with EN 13240.
PREPARATORY WORK AND SAFETY CHECKS
IMPORTANT WARNING
This stove must not be installed into a chimney that serves any other heating appliance. There must not be an
extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room.
CHIMNEY
Chimney Connection
Flue Diameter 125 mm
IMPORTANT: Once the stove is unpacked and checked it is necessary to remove the central bar from the flue collar of
the stove before installation. To remove unbolt collar remove bar and replace collar.
When installing your stove with a 125 mm /5” flue please ensure to fill drain hole at rear of cast collar with fire
cement so to prevent any potential leakage of flue gases. Use a proprietary brand of heat resistant fire cement and
ensure that enough cement is used to completely fill the area.
In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate
draught so as to clear the products of combustion and prevent smoke problems into the room.
Minimum draft: UNIQ36/ WF36 Pedestal and UNIQ37/ WF37 Pedestal stoves has been tested with a draft of
12 Pa. Maximum draft 25 Pa.
Flue gas flow 7.0 g/sec.
Flue gas temperature 303°C. approximately 12 Pa.
NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of
the chimney should be satisfactory. Alternatively the calculation procedure given in BS 5854:1980 may be used as
the basis for deciding whether a particular chimney design will provide sufficient draught.
The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building
Regulations Approved Document J.
If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow
fumes into the house. Older properties, especially, may have chimney faults or the cross section may be too large
i.e. more than 160 mm x 160 mm. Remedial action should be taken, if required, seeking expert advice, if necessary.
If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in accordance with
Building Regulations Approved Document J.
Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of the
stove. If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Westfire WF36 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Westfire WF36 in the language / languages: English, German, Dutch, Danish, French as an attachment in your email.

The manual is 3.24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info