17
RE-FUELING
To re-fuel your stove in the cleanest way.
Only refuel your stove when flames have died down and you have glowing embers.
Before refuelling, open secondary air control fully, also open primary air control fully and leave for 5 minutes.
Open door gently, add four pieces of wood measuring approx 22cm with a combined weight of approx 2.1kg
and close the door. Leave the air controls open for 10 minutes to allow the fire to reach a good temperature.
Close (push in) primary air control and slide secondary air control to position for the stove.
In the event of a chimney fire: Close the air controls and the stove door, and call 999 or your local fire
department.
If your stove is overheating close all air controls, ensure door is firmly closed, leave stove until it has returned to
nominal temperature.
Basic Positions of air controls during operation (nominal)
Secondary air Primary air
WF32/UNIQ32 100% open closed
You will need to become familiar with your stove in order to be able to regulate the secondary air intake correctly,
as factors such as the quality and height of your chimney, the quality of your fuel and the external conditions
play a large role in your stove performance. It is easy to see whether the stove is functioning correctly; however
incomplete combustion may lead to a build-up of hard, shiny soot on the inside of your stove and glass.
To prevent sooting of the chamber and glass introduce secondary air, also check that your wood is dry.
It is important to check the draft conditions before lighting your stove. This may be done, for instance, by
crumpling a piece of newspaper, placing it in the combustion chamber and lighting it. The draft conditions are
good if the smoke is drawn away through the chimney.
STOVES CONTROLS
Door operation
When opening the door of your Westfire stove always wear the glove that is provided to protect your hand from
possible heat.
PRIMARY AIR
IN/CLOSED, OUT/OPEN
SECONDARY AIR
IN/CLOSED, OUT/OPEN
DOOR HANDLE
UK
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Westfire WF32 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Westfire WF32 in the language / languages: English, German, Dutch, Danish, French as an attachment in your email.

The manual is 2.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info