10. 2 EXPLANATION DATA STRING RECEIPT
The comport is full duplex: receipt and transmission may occur at the same time.
A new command for the same activity deletes the previous one if that one not yet had been executed.
It is advised to send some spaces (f.e. CR’s) in between strings that are sent direct after one another.
This may happen f.e. by sending several setpoint values for different (course - fine dosing) setpoints.
After sending a setpoint value, this value may be requested to be send in return, in order to check the correct
receipt of the command (echo). The same command as sent should be returned by the 348 with only a “#” in
digit 2 as difference. Code”#” means this is a transmission from a 348.
There are 2 different kind of strings that may be sent to a 348: :
10. 2. 1 QUESTION
Index: Always a ? in the 2
nd
digit
The receipt of a question does not start any action of the 348, but creates an answer only.
In continuous sending mode (call nr. 0=A) a 348 sends continuously with the string “weight
data” the gross or the nett weight + standard data.
If in this mode a “setpoint” or “info” request is received, the required information is sent one
time only, thereafter the previous transmission is continued.
Available questions are:
X ? G What is the gross weight ?
X ? N What is the net weight ?
X ? T What is the tare weight ? (= gross -/- net)
X ? Z What is the zero value compensation ?
(= the weight selected at power on, subtracted from signal input to create an exact
zero, dead load switch settings excluded)
X ? S .. What is the weight value and status of setpoint nr. .. (A, B, D or H = 1, 2, 3, or 4)
X ? S @ What is the gross A/D converter output (in high resolution 1:2,000,000) ?
X ? H What is the 348’s internal temperature, and excitation voltage of the loadcells ?
10. 2. 2 COMMAND
Index: Always a ! in the 2
nd
digit
A received command will cause immediate action of the 348.
If the required action is not possible to execute, the 348 will show a status report in digit
3, 4, 11 or 12 of the string “weight”, indicating why the action is not, or later will be executed.
Available commands are:
X ! G Set gross = cancel tare
X ! N Set nett = start tare operation to zero, after -waiting for- no motion of the
weight value *)
After the tare operation, a 348 in continuous sending mode (nr. 0) will
automatically switch over to transmit the nett weight in data string “weight”.
X ! Z Set zero, executable only within the -1.3%...+2.7% of scale capacity.
X ! S W--W. . Set the setpoint value (x10) W--W, and the executive code for setpoint nr. ..
X ! R .. .. Start of stop one or more setpoints nr(s) .. with filter code ..
X ! E Special commands and resets
*) Attention! The command X ! T does not exist. The tare command is : X ! N
Manual 348-2 V 3.1 Page 34 01-06-2007
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Weightec 348 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Weightec 348 in the language / languages: English as an attachment in your email.

The manual is 1,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Weightec 348

Weightec 348 User Manual - Dutch - 49 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info