Exceeding the zero limits : As soon as a zero setting should exceed the limits, the zero setting is not
executed. In the data string, in digit 12, an error message appears : > or = ,
as well as on the internal display in the last two characters : Z > or Z = .
The previous zero value is maintained and may be requested for with
command : ? Z .
Delete zero memory : Both the zero memories of the zero track en initial zero setting are deleted
by setting both switch 4 and 5 off.
The zero memories are not deleted by switching off the 348.
4.3 ADJUSTING : DEAD LOAD COMPENSATION SWITCH 6 - 16
System : Dead load compensations used for suppressing permanent loads on a
weighing scale. F.e. a weigh hopper, platform, conveyor etc.
Here the dilswitches 6 up to 16 are used as hardware memory. The setting of
these switches is continuously transferred to a digital memory and is
subtracted from the actual A/D conversion value.
At any moment the setting of the switches may be changed, the weight reading
is adapted immediately.
Range : The 11 dilswitches have a total range of 1 mV/V, that is 50 % of the capacity of
2 mV/V loadcells. If this proves to be not enough a higher capacity of loadcells
should be applied.
Accuracy : The first switch at the left: switch 6, has the highest value: 50% of the range,
the next has 25% and so on until switch 16 with 0.05% effect, which is 0.1%
of the weighing capacity. These lasting 0.1% is set zero with switch 5 . See 4.2.
Procedure : Start with all the switches down (off), 4 and 5 included. Set switch 6 “on” and
check the effect on the internal display. If the weight value still is positive leave
the switch “on”. If the value is negative set the switch back “off”.
Proceed with switch 7 a.s.o. until switch 16. Finally switch 5 is set “on”
resulting in an exact zero reading.
Attention
: during this procedure all the span switches 17 t/m 32 should be “on”,
the division selector switches preferably at x 1: switches 53 up to 56 op 1 0 0 1
(on -off - off - on). Not all the overload switches 38 up to 48 should be “off” ,
preferably all “on” .
No interference with : Setting or changing the dead load settings and the digital zero memories
span adjustment does not effect in any way the span adjustment.
4.4 ADJUSTING : SPAN SWITCH 17 - 32
Weight adjustment : Using switch 17 up to 32 the scale may be adjusted, based upon an accurate
weight mass placed upon the scale, preferably 100% of the weighing capacity.
These switches determine the number of scale divisions that are applied on the
selected input sensitivity range. See 4.1
F.e. at an selected input range of 1 mV/V, the input signal of 1 mV/V is
divided into 15,000 divisions if all the switches are “on”. Setting back the
switches one by one will reduce this number, finally to 0 divisions.
At any moment the setting of the switches may be changed, the weight reading
is adapted immediately.
Manual 348-2 V 3.1 Page 14 01-06-2007
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Weightec 348 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Weightec 348 in the language / languages: English as an attachment in your email.

The manual is 1,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Weightec 348

Weightec 348 User Manual - Dutch - 49 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info