4.7.1 Draining the boiler manually
Drain water contents manually when there is risk of frost and
when storing the vehicle for a longer period.
Both manual and programmable control panel:
1. Interrupt power for vehicle system water pump (main
switch or pump switch, depending on instructions of the
vehicle manufacturer).
2. Open hot water taps in kitchen, bathroom, shower, etc.
(set preselecting mixing taps or single-lever valves to
"hot").
If you have manual control panel, then continue with fol-
lowing steps:
1. The electrical safety/drain valve is opened by turning and
holding the mode selector knob (A) against the spring force
in the position drain boiler (6) for at least 5 seconds.
2. Then, release the knob. The electrical safety/drainage valve
will be open for approx. 90 minutes.
3. During drainage, all green icons on the control panel, as
well as the red indicator on the mode selector knob (A), are
blinking.
The boiler content is now discharged to the outside through the
electrical safety/drainage valve.
Place a container beneath the outlet to check whether the wa-
ter in the boiler has completely drained away (approx. 9 litres!).
If you have programmable control panel, then continue
with the following steps:
1. Make sure the device is switched on.
2. Press MENU.
3. Press and to select “ Draining Boiler”.
4. Press OK. The display shows: “Press OK to confirm boiler
drainage
5. Press OK. The display shows:
Draining... Press MENU to select heating operation
and
Press STOP to abort drainage” “ ” (9)
NOTE
Any kind of heater operation will be stopped when
manually starting boiler drainage.
NOTE
To stop drainage see chapter4.7.2, "How to stop drain-
ing the boiler" on page 14.
uThe boiler content is now discharged to the outside
through the electrical safety/ drainage valve.
uPlace a container beneath the outlet to check
whether the water in the boiler has completely
drained away (approx. 9 litres!).
uAfter approx. 90 min, the message “Drainage com-
pleted” is shown.
1. Press OK to end manual drainage.
NOTE
Any kind of water from the vehicle has to be discharged
at an appropriate disposal facility.
NOTE
Avoid the formation of micro-organisms in the lines and
in the boiler during storage and make sure that the wa-
ter supply system is completely drained. To do this,
open all water valves, connect an air pressure of ap-
prox. 2 bar to the hot water line and leave it connected
until the residual water is completely drained off.
4.7.2 How to stop draining the boiler
For heaters with a manual control panel, you can stop drainage
by moving mode selector knob (A) to drainage mode (6) for at
least 5 seconds and than releasing the knob.
In case of a programmable control panel, you can stop boiler
drainage, if needed.
1. Make sure the device is switched on.
2. Press MENU.
3. Press and to select “ Draining Boiler”.
4. Press OK.
5. The display shows “Press OK to confirm boiler drain-
age”. Press OK.
The display shows:
Drainage... Press MENU to select heating operation
Press STOP to abort drainage” “ ” (9).
6. Press STOP.
The display shows: “Drainage aborted”.
7. Press OK.
4.7.3 Draining the boiler automatically
The electrical safety/drainage valve is opened electrically.
If the water temperature at the electrical safety/drainage valve is
less than 6 °C, the boiler water contents may discharge auto-
matically.
This function is active when:
nthe device is switched "OFF";
nin winter mode (heating without hot water production)
during a period when there is no heating action in the
heater (e.g.: selected interior temperature is reached, low
outside temperature);
nif battery power is too low;
nthere is a failure!
NOTE
Note that the electrical safety/drainage valve only works
when a 12 V power supply is available!
With a manual control panel, during drainage, all green icons,
as well as the red indicator on the mode selector knob (A), are
blinking.
With a programmable control panel, during drainage “ ” (9)
appears on display.
After approx. 90 min, the electrical safety/drainage valve will be
closed again.
The drainage outlet of the electrical safety/drainage valve must
always be kept clear (free from dirt, ice, leaves etc.)!
To avoid water loss and to protect the heater and boiler against
frost, select the frost protection mode (see chapter4.7.4, "Frost
protection" on page 15 ).
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Webasto Dual Top ST 8 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Webasto Dual Top ST 8 in the language / languages: English as an attachment in your email.

The manual is 6.42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Webasto Dual Top ST 8

Webasto Dual Top ST 8 User Manual - German - 21 pages

Webasto Dual Top ST 8 User Manual - Dutch - 21 pages

Webasto Dual Top ST 8 User Manual - French - 21 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info