802208
19
Zoom out
Zoom in
Previous page
1/32
Next page
19
CONTROL DEVICE PARAMETERS TABLE
The table below shows in bold face the suggested control parameters (1st level programming) that
require modification of the control device Default settings if the system has the electric defroster
See the control device user’s manual for the meaning of the individual parameter abbreviations
used in the first column of this table.
- Setting to be arranged when the simplified hot gas “DEFROST” device is used, for abo-
ve zero temperature applications.
- It activates Neutral Zone Operation
Parameter Range 1st
level
Default settings Units
of
measure
R134a R404A
SEt LS US 00°C
Hy 0,1°C 25,5°C 2 2 °C
LS -50°C SEt 0-20°C
US SEt 110°C 30 30 °C
Ot -12°C 12°C 0 0 °C
P2P n/y yy-
OE -12°C 12°C 0 0 °C
odS 0 255 0 0 Minutes
db n/y n n (y)-
AC 0 50 1 1 Minutes
CCt 0 24 0 0 Hours
CCS -55150°C 0 0 °C
COn 0 255 15 15 Minutes
COF 0 255 30 30 Minutes
CF °C °F °C °C -
rES in / dE dE dE °C
Lod P1 / P2 P1 P1 -
tdF EL / in EL(in)in-
dtE -50°C 50°C 2(5)5°C
IdF 0 120 1(3)3Hours
MdF 0 250 8(5) 5 Minutes
dSd 0 59 0 0 Minutes
dFd rt / set / it / dEF dEF dEF -
dAd 0 255 1 1 Minutes
Fdt 0 120 1 1 Minutes CAUTION:
for technical or commercial reasons, Webasto Diavia reserves the right to modify
this publication at any time without prior notice.
Reproduction or translation of even a part of the present manual is forbidden wi-
thout written authorization Webasto Diavia.
Parameter Range 1st
level
Default settings Units
of
measure
R134a R404A
dPo n / y n n -
dAF 0 23,5 0 0 Hours
Fnc C-n / o-n
C-y / o-y C-y C-n -
Fnd 0 255 0 0 Minutes
FSt -50°C 50°C 50 50 °C
Fon 0 15 0 0 Minutes
Fof 0 15 0 0 Minutes
ALC Ab / re Ab Ab -
ALU ALL 110°C 110 110 °C
ALL -50°C ALU -50 -50 °C
ALd 0 255 15 15 Minutes
dAO 0 min 23h 50’ 1.3 1.3 H/Min
i1P oP / cL cL cL -
i1F EA / bAL / PAL
dor / dEF / onF
Htr / ES dor PAL -
did 0 255 15 10 Minutes
nPS 1 15 15 5 -
odc no / Fan
CPr / F_C no no -
PbC Ptc Ntc Ntc Ntc -
onF nu / oFF / ES oFF oFF -
dP1 - ---
dP2 - ---
rEl - - - -
Ptb - - - -
ENGLISH
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Webasto Diavia PORDOI 2000 - 3000 - 4000 - 5000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Webasto Diavia PORDOI 2000 - 3000 - 4000 - 5000 in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 3.04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info