Menu structure
Service
English “Language”
Time and date
o Time
o Date
o 24/12h clock
o DST
System
o System 1 - 8
o System Parameter (if available)
Outputs Configuration
o P1 “Information of the use”
o P2 “Information of the use”
o P3 “Information of the use”
Inputs Configuration
o Fixed Flowrate value
Flow (l/min)
o Grundfos sensors
GDS1”Sensor choice”
GDS2 ”Sensor choice”
o Impulse flow meter
T6
Liter/Impulse
o Temperature Sensors
T1- T5
Calibration (Pt-1000)
Energy Measurements
o Solar Energy
Adjustments
o 2nd Energy
Adjustments
Protection func.
o Max temp coll.
o Overheat prot.
Overheat temp
o Cooling
Max temp
o Recooling
Min temp
o Freeze prot.
Freeze Temp
Degrees °C/°F
Tube collectors
Factory setting
Quick start menu
o Configuration sequence
Settings
Maxtemp tank1
dT.ON tank1
dT OFF tank1
“Only available with system with 2 tanks”
Maxtemp tank2
dT.ON tank2
dT OFF tank2
“Only available with system 6”
dT.ON return
dT OFF return
dT FS
Mintemp coll.
“Only available if P3 is used as an Extra function”
Extra Function adjustments
Operation
Automatic
Off
Chimney sweep
Manual testing
Operation h
Operation
dT
Power
Energy
SD card
Temperatures
T1
T2
T3
T4
T5
MAIN CHARACTERISTICS
- Large graphic display with backlight
- Easy use interface (4 keys with scroll menu).
- Several languages available
- SD card interface to save the recorded statistics
(Temperatures, Power, Energy, Time operation…) and
parameters.
- 2 energy counters (1 for solar energy and 1 free to specify).
- 1 Bus connection (RJ45) for Extension module (MULTIPLEX)
and communication option.
- Graphic view for Temperature, power, energy…
- 8 working systems with several extra functions possibility
- 5 Inputs for temperature sensors (PT1000 type)
- 1 Logical Input for Impulse flow meter input (for energy
measurement).
- 2 Analogue inputs for Grundfos direct sensors (Flow,
Pressure and temperature sensor)
- 2 electronics outputs for pump (Standard or PWM) with pump
exercise function.
- 1 standard output for Extra function (to control additional
heat, cooling system…)
- Automatic, Off, Manual test mode and chimney sweep
function.
- Sensors Auto checks (Short circuit and breaks)
- Collector protection (Freeze and overheat)
- Permanent memory storage
TECHNICAL CHARACTERISTICS
Operating temperature
0°C 50°C
Electrical Protection
Installation Category
Pollution Degree
IP20
CLASS I
2
Fusible
Power supply
Maximum Power
Consumption
(with all outputs activated)
5AType Fuse 230Vac
(5x20mm)
230Vac +/- 10% 50Hz
4,7A (~ 1080W)
Outputs:
P1 (Main pump with standard
or PWM speed regulation):
P2 (Pump with standard or
PWM speed regulation, valve):
P3 (Extra, Additional heat,
cooling…)
Triac max. 1A 230VAC.
Minimum power switching
>1W
Triac max. 1A 230VAC.
Minimum power switching
>1W
Relay max. 2A 230VAC
* Higher power
consumption: only possible
with external power relay
Inputs:
T1 (Collector1):
T2 (Tank1):
T3 (Extra sensor):
T4 (Extra sensor, Tank2,
Collector2):
T5 (Collector return):
T6 (Flow meter):
GDS1 & GDS2 (Grundfos
sensor):
Flow or pressure.
PT 1000 type
PT 1000 type
PT 1000 type
PT 1000 type
PT 1000 type
Impulse type (low voltage
5V)
Analogue type
(Grundfos VFS, RPS)
Sensors delivered with the
product:
2 Collectors sensor (red)
1 Tank (grey)
1 Extra (grey)
PT1000 (1.5M 180°C)
PT1000 (3M 105°C)
PT1000 (3M 105°C )
Software version
Displayed during
initialisation
Higher Version 11xx
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Watts Solar Controller LCD PLUS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Watts Solar Controller LCD PLUS in the language / languages: English, German as an attachment in your email.

The manual is 1.12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info