Your gas hearth must only be installed by a certified
installer and only in combination with the WANDERS
concentric pipe system. Only then will the hearth be
approved according to the European CE standards for
gas appliances. We will not give any guarantees if the
gas hearth is fitted and/or installed in an incomplete or
improper manner. The pipe system consists of an inner
pipe with a diameter of 100 millimetres and an outer
pipe with a diameter of 150 millimetres.
The appliance may only be installed and fitted by a
certified installer in accordance with current universal
gas piping regulations and according to the installation
instructions mentioned below. Furthermore, the
national and local rules and regulations on placing and
using closed gas appliances shall be applicable. Only
certified installers are authorized to change the preset
values (in line with the regulations) or make any other
adjustments.
Before installing the appliance, the installer must check
whether the information on the type tag of the fireplace
corresponds with the gas type and gas pressure to which
the appliance is connected. If it does not match, it is not
allowed to connect the gas unit.
Placing
The gas hearth must not be built into the wall. The
distance from the hearth to the rear wall must be at least
10 cm. The gas hearth must be placed on a floor that is
solid enough to hold it.
The gas hearth can be placed in a crack-free and/or
mechanically ventilated home without difficulty. There
is no need for extra ventilation for combustion, or for
a smoke and fire vent. Waste gases are discharged by
natural draught via the inner pipe into the open. The
oxygen needed for burning the fire is supplied from
the space between the pipes. This is the reason that no
Installation instructions
General instructions 23
Placing of the concentric channel system 24
Installation 25
Completing the installation 26
Technical data for kind of gas and consumption 28
insulation must be placed between the inner and the
outer pipe.
Insulation
Due to the high temperatures of the exterior walls (up to
approximately 150 °C or 300 °F) it is prohibited to have
any combustible materials close to the channel system.
The entire concentric pipe system should be encased
(heat resistant) from the place where it is out of sight up
to the outlet in the exterior wall. Ventilate the encased
concentric pipe system by placing a grid near the floor
and the ceiling on every floor. Use universal wall clips
with a diameter of 150 mm for anchoring the concentric
pipe system.
If an existing chimney is used, first make sure whether
the chimney is sufficiently insulated and with sufficient
diameter to accommodated the concentric pipe system.
If the chimney was previously used as a wood-burning or
coal-fired stove, the chimney must first be professionally
cleaned. You must use special WANDERS connecting
sets for connecting a gas hearth to an existing chimney.
Gas connection
• Use a feed pipe with an approved G3/8” stop cock
with coupling.
• De-aerate the supply pipe before fitting and fastening
the appliance.
• Avoid all tension on the operating valve and pipes to
avoid gas leakage.
• Check if the connection is gastight.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wanders Norma Free at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wanders Norma Free in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info