813266
35
Zoom out
Zoom in
Previous page
1/104
Next page
35
1.7 Safe distances
The following distances must be respected as safety margins from flammable objects and
bearing walls made of reinforced concrete and partition walls made from flammable mate-
rials or covered in flammable materials:
Beneath the hob plate (from the top of the stove to the floor)
A ≥ 800 mm B ≥ 3 mm* C ≥ 200 mm
Above the hob plate (radiation area of the hob plate)
A ≥ 800 mm B ≥ 300 mm C ≥ 200 mm
* The silicon dividers which are supplied must be fitted to the side panel to ensure
this.
Any flammable items attached above the stove must kept at a suitable distance. The mini-
mum distance is 800 mm.
Floor in front of the stove
Floors made of flammable substances, such as e.g. carpets, parquet, laminate, plastics or
cork, must be replaced or covered by a non-flammable substance e.g. ceramic, stone,
glass or a steel floor-plate for a distance of 500 mm forwards and 300 mm sideways.
The connection piece must not pass between flammable building materials or furniture. If
connected at the side, the safety gap required by the manufacturer between it and any
flammable materials must be respected.
1.8 Chimney attachment
The connection for attaching to the chimney must be able to withstand at least 400°C.
PLEASE NOTE:
Before connecting the stove the local authority responsible for approving heating
systems must be consulted!
Connection pieces must be firmly connected to the stove and to each other and must not
leak. They must not project into the open diameter of the chimney. The connection piece
between the stove and the chimney must have the same diameter as the pipe socket on
the stove. Horizontal connection pieces of over 0.5 m must rise towards the chimney at an
B
B
A
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wamsler W1-90 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wamsler W1-90 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 1.83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info