4.3 Integrating in an existing unit
The stove with integrated heat exchanger for the heat sink is suitable for incorporating in
existing units which are constructed as closed systems.
The safety valve on the central heating boiler in the cellar cannot cover the heating stove
as well. A separate safety valve should in any case be provided near the heating stove.
It is absolutely necessary to consume, respectively to store up the energy of the added
cooker. A buffer reservoir of 50 litres per kW water output is normally sufficient for buffer-
ing.
5. TECHNICAL DATA
5.1 Fuel
Low smoke, trouble-free operation of the stove and a supply of heat at the nominal level
with a chimney draught of 12 Pa are only guaranteed when you use the following fuels and
no others.
Only use natural, dry chopped firewood with a remaining humidity of max. 20% and lignite
(brown coal) briquettes.
Fuel type
Thermal content approx.
Comment
Lignite briquettes
Hardwood air dry
Softwood air dry
19,500 kJ/kg
14,600 kJ/kg
11,500 kJ/kg
Slow burning only possible
to a limited extent
No slack and no in chips or smoke intensive rubbish to be burnt.
Non-permitted fuels include:
Rubbish, fine chips, pellets, bark, parts of chipboards, coal slack, damp wood or wood
treated with preservative, paper, cardboard or similar. For lighting use wood shavings or
barbecue lighters. Never use liquid fire starters!
PLEASE NOTE:
The first time the stove is heated there may be some smoke and an unpleasant
smell. Make sure that the room is well ventilated (open windows and doors) and heat
for at least an hour at the maximum nominal heat load. If the maximum temperature
is not reached the first time the stove is heated, then there may be further unpleas-
ant smells at a later date.
52


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Wamsler K148F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Wamsler K148F in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 3.9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info