Keep a minimum distance of 10 m between any electrode of the energiser and other
grounding systems (e.g. protective grounding of a power distribution system or a
grounding of a telecommunication system).
Ensure that connection lines that are routed inside buildings are eectively insulated
from earthed, load-bearing parts of the building. To ensure this, use insulated high-
voltage cables.
Ensure that underground connection lines are routed through electrical conduits made
from insulating material or otherwise use insulated high-voltage cables.
Ensure that connection lines are not damaged by sinking animal hooves or tractor
wheels.
When installing the electric animal fence, do not use the electric conduit from any
external sources, third parties i.e. telecommunication companies or the main power
conduit entering the building.
The electric animal fence must be no less than 2.5 m away from earthed, metallic
objects (e.g. drinking troughs, water pipes). This is particularly important in areas
where people may be present.
Do not cross connection lines and electric animal fence wires over high-voltage or
communication lines.
Avoid crossings with high-voltage lines. If this cannot be avoided, the crossing must be
made below the power line at a 90° angle and as close as possible.
Do not power an electric animal fence with two separate electric fence energisers or
from the independent fence circuits of the same energiser.
Barbed wire or razor wire must not be electried with an energiser.
Non-electried barbed wire or razor wire may be used to support one or more
oset electried wires of an electric animal fence. The electried wires must be kept
at a vertical distance of at least 150 mm from the non-electried wires by means of
supports. Make sure that the non-electried wire is earthed at regular intervals.
There must be a minimum distance of 2.5 m between two separate electric animal
fences, which are powered by separate independently clocked electric fence energisers.
If there should be a physical barrier between the fences then only use electrically non-
conductive materials or an insulated metal barrier.
Ensure that all mains-operated auxiliary equipment connected to the electric animal
fence has the same degree of insulation as the energiser used.
Ensure that the auxiliary equipment is weatherproof. Outdoor use is only permitted if
it has been certied by the manufacturer and the equipment has a minimum degree
of protection of IPX4.
2.3 Safety during Operation
Lightning can cause res and lead to malfunctions on electric fences. Separating the
energiser from the fence and power source before a storm or possible lightning strike
can minimise the eects of lightning. Redirect the current of the lightning strike to the
ground before it damages the energiser by installing a lightning rod between the fence
and the energiser.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voss Impuls duo at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voss Impuls duo in the language / languages: English, German, Dutch, French, Italian, Polish, Swedish, Spanish as an attachment in your email.

The manual is 7,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Voss Impuls duo

Voss Impuls duo User Manual - English - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info