Proceed as follows to measure direct currents of up to 250 mA/DC:
- For measuring in the mA/µA range, select the corresponding measuring range.
- Connect the black measuring line with the COM socket (6) and the red measuring line with the mA
socket (7).
- Now perform null balancing.
- Observe the correct polarity (red = + / black = -) and connect the
two test prods in series with the test object (battery, circuit, etc.).
- If the polarity is not correct, no value is displayed. The built-in pro-
tective diode prevents the measurement. Stop measuring and
measure again observing the right polarity.
- Read off the measured value on the “A” scale.
- After measuring, put the rotary switch in the “OFF” position to turn
off the multimeter.
e) Acoustic continuity check
ƽ
Make sure that all circuit parts, switches, components and any other test objects are
currentless and discharged.
The continuity check allows a quick check e.g. of a line. If forward resistance is <200 Ohm, a beep
sounds with the displayed measuring result.
To measure, proceed as follows:
- Select the measuring range on the rotary switch . -
- Connect the black measuring line with the COM socket (6) and
the red measuring line with the VΩ socket (7).
- Now perform null balancing.
- Connect the two test prods with each other and wait until the
pointer has stabilised. A value of approx. 0 Ohm must be dis-
played. In case of a deviation, adjust the pointer to 0 Ohm using
the 0 Ohm calibration control (9). If calibration fails, the two AA
batteries have to be replaced.
- Now connect the two test prods to the test object (component, switch etc.).
- Read off the measured value on the “Ω” scale. A beep sounds when the resistance value is <200
Ohm.
- After measuring, put the rotary switch in the “OFF” position to turn off the multimeter.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC5070 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC5070 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info