j) Capacity Measuring
ƽ
Make sure that all the circuit parts, switches and components and other objects of
measurement are disconnected from the voltage and discharged.
With electrolyte capacitors, ensure that you observe the polarity.
- Switch on the DMM and select measuring range
.
- Plug the red measuring lead into the V measuring socket (7) and the
black measuring lead into the COM measuring socket (8).
- The display shows the unit “nF”.
Due to the sensitive measuring input, the display may show a
value in case of “open” measuring lines. By pressing the button
“REL”, the display is set to “0”. The Auto range function
remains active.
- Now connect the two test prods (red = positive pole/black = negative pole) with the object to be mea-
sured (condenser). After a short while the display shows the capacity. Wait until the displayed value
has stabilised. With capacities of >40 µF, this may take a few seconds.
- If “OL” (overload) appears on the display, you have exceeded the measuring range.
- After measuring, remove the measuring lines from the measured object and turn the DMM off.
REL Function
The REL function allows a reference value measurement to avoid possible line losses which may caused
e.g. during resistance measurements. For this purpose, the current indicated value is set to zero. A new
reference value is set.
Press the “REL” button to activate this measuring function. The display indicates “ “. The automatic
measuring range selection is deactivated now (except for capacity measuring range).
To deactivate this function, switch the measuring function.
ƽ
The REL function is not active in the frequency measuring range and for the high-
impedance resistance measuring range, diode tests and continuity tests.
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC265 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC265 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info