42
d) Fuse change
The current measuring ranges are protected against overload with high-performance fuses. If no measurements in
the current measuring range are possible anymore, the fuses are probably defective and need to be replaced.
Check the fuses:
The fuses can be checked for their function with the casing closed. The test requires only one measuring line.
Switch on the meter and select the measuring function “continuity test”.
Insert the measuring lines into the V measuring socket (7).
Touch the measuring prod to the measuring socket “COM” (6). If a beep sounds, the fuse for the mA/µA measuring
range is OK. If there is no sound, the fuse is defective.
Touch the measuring prod to the measuring socket “10A” (5). If a beep sounds, the fuse for the 10A measuring
range is OK. If there is no sound, the fuse is defective.
Always observe the safety provisions during use changes!
Ensure that only fuses of the indicated type and rated current must be used as spares. Use of
wrong or patched-up fuses or bridging of the fuse holder is not permitted and may cause re.
Proceed as follows for fuse replacement:
- Disconnect the connected measuring lines from the
measuring circuit and the meter. Switch off the DMM.
- Loosen the three rear housing screws with a matching
Phillips screwdriver. Carefully disconnect the two casing
halves.
- Replace the defective fuse with a new fuse of the same
type and rated current.
Fuse F1: FF0.2A H 600 V 6.3 x 32 mm
Fuse F2: F10A H 600 V 6.3 x 25 mm
However, always observe the information at the device or
the values of the fuse used.
- Close and screw shut the casing carefully again in the
reverse order.
Never operate the meter when it is open. !DANGER TO LIFE!
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC165 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC165 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info