Maintenance and cleaning
General
To ensure the accuracy of the multimeter over an extended period of time, it should be calibrated once a
year.
Apart from occasional cleaning and fuse replacements, the multimeter requires no servicing.
Information on changing the battery and fuse appears below.
ƽ
Regularly check the technical safety of the instrument and measuring lines, e.g.
check for damage to the housing or squeezing etc.
Cleaning
Always observe the following safety instructions before cleaning the device:
ƽ
Live components may be exposed if covers are opened or parts are removed (unless
this can be done without tools).
The connected lines must be disconnected from the measuring device and all mea-
suring objects prior to cleaning or repairing the device. Switch the DMM off.
Do not use any carbon-containing cleaning agents or petrol, alcohol or the like to clean the product.
These could corrode the surface of the measuring instrument. Furthermore, the fumes are hazardous to
your health and explosive. Moreover, you should not use sharp-edged tools, screwdrivers or metal
brushes or similar for cleaning.
For cleaning the device or the display and the measuring lines, use a clean, fuzz-free, antistatic slightly
damp cloth.
Fuse replacement
The currency measuring ranges are protected against overload with ceramic fine-wire fuses. If measur-
ing in this range is no longer possible, you have to change the fuse.
Proceed as follows for replacement
- Separate the connected measuring leads from the measuring circuit and the measuring device.
Switch the DMM off.
- Unscrew the three screws on the back of the device and carefully pull the casing apart.
- Replace the defective fuse with a new fuse of the same type and nominal voltage. The fuses have the
following values:
F1 fine-wire fuse, quick-action, 1A/250 V (6 x 25 mm). Common name F1A250V.
F2 fine-wire fuse, quick-action, 10A/250 V (6 x 25 mm). Common name F10A250V.
- Now close the housing carefully again.
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC130 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC130 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info