Measuring socket selection and assignment of the black and red measuring cable
DMM black red
VC130 COM (5) mA/Ω (7)
VC150 COM (5) mA/Ω (7)
VC170 COM (5) V/Ω (8)
- Turn the DMM on and select measuring range
- Insert the measuring cables in line with the model into the corresponding measuring sockets as
shown in the table.
- Check the measuring leads for continuity by connecting both measuring prods to one another. After
that the value must be approximately 0 V. The open-circuit voltage is approx. 3 V.
- Now connect the two measuring prods with the object to be measu-
red (diode).
- The display shows the continuity voltage in volt (V).
- If “OL” is indicated, the diode is measured in reverse direction or the
diode is faulty (interruption). Perform a counter-pole measuring for
control reasons. The red measuring lead corresponds to the positive
pole (anode), the black measuring lead to the negative pole (cath-
ode).
Asilicone diode has an on-state voltage of approx. 0.5 – 0.8 V
.
- After measuring, remove the measuring leads from the measuring object and turn the DMM off. Turn
the rotary switch to the position “OFF” or turn the device off via the “POWER” switch.
f) Continuity check
ƽ
Make sure that all the circuit parts, switches and components and other objects of
measurement are disconnected from the voltage and discharged.
Measuring socket selection and assignment of the black and red measuring cable
DMM black red
VC130 COM (5) mA/Ω (7)
VC150 COM (5) mA/Ω (7)
VC170 COM (5) V/Ω (8)
- Turn the DMM on and select measuring range
- Insert the measuring cables in line with the model into the corresponding measuring sockets as
shown in the table.
- To activate the acoustic continuity tester function, press the button “SELECT” (3). Pressing this but-
ton again takes you back to the first measuring function (diode test) etc.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC100 serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC100 serie in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info