4. SYMBOL EXPLANATION
An exclamation mark in a triangle shows important notes in these operating instructions
that must be strictly observed.
The triangle containing a lightning symbol warns against danger of electric shock or
impairment of the electrical safety of the device.
The “arrow” symbol indicates that special advice and notes on operation are provided.
This device is CE-compliant and meets the necessary European directives.
Protection class 2 insulation (double or reinforced insulation)
CAT II
Overvoltage category II for measurements on electric and electronic devices connected
to the mains supply with a mains plug. This category also covers all lower categories (e.g.
CAT I for measuring signal and control voltages).
CAT III
Overvoltage category III for measuring in building installation (e.g. outlets or sub-
distribution). This category also covers all lower categories (e.g. CAT II for measuring
electronic devices).
CAT IV
Overvoltage category IV for measuring at the source of the low-voltage installation (e.g.
main distribution, house-transfer points of energy providers, etc.) This category also
contains all lower categories.
Earth potential
123
Tension alternative
Plage Résolution Précision Gamme de fréquence
6 V 0,0001 V
±(0,5 % + 40 digit) 45 Hz – 1 kHz
±(1,2 % + 40 digit) 1 kHz - 10 kHz
±(3 % + 40 digit) 10 kHz - 20 kHz
±(4 % + 40 digit) 20 kHz - 100 kHz
60 V 0,001 V
±(0,5 % + 40 digit) 45 Hz - 1kHz
±(1,2 % + 40 digit) 1 kHz - 10 kHz
±(3 % + 40 digit) 10 kHz - 20 kHz
±(6 % + 40 digit) 20 kHz - 100 kHz
600 V 0,01 V
±(0,5 % + 40 digit) 45 Hz - 1kHz
±(1,2 % + 40 digit) 1 kHz - 10 kHz
±(3 % + 40 digit) 10 kHz - 20 kHz
non spéci é 20 kHz - 100 kHz
1000 V 0,1 V
±(1,2 % + 40 digit) 45 Hz - 1kHz
±(3 % + 40 digit) 1 kHz - 5 kHz
±(6 % + 40 digit) 5 kHz - 10 kHz
non spéci é 10 kHz - 100 kHz
Protection contre la surcharge : 1000 V ; impédance : env. 10 M
TrueRMS dans une plage de mesure de 10 – 100 %
Facteur de crête (Crest Factor ) : max. 3,0 (à 1000 V max. 1,5)
Fonction de mesure de la tension CA + CC
Plage Résolution Précision Gamme de fréquence
6 V 0,0001 V
±(1 % + 80 digit) 45 Hz - 1 kHz
±(3 % + 40 digit) 1 kHz - 10 kHz
±(6 % + 40 digit) 10 kHz - 35 kHz
60 V 0,001 V
±(1 % + 80 digit) 45 Hz - 1 kHz
±(3 % + 40 digit) 1 kHz - 10 kHz
±(6 % + 40 digit) 10 kHz - 35 kHz
600 V 0,01 V
±(1 % + 80 digit) 45 Hz - 1 kHz
non spéci é 1 kHz - 10 kHz
non spéci é 10 kHz - 35 kHz
1000 V 0,1 V
±(1,2 % + 80 digit) 45 Hz - 1 kHz
non spéci é 1 kHz - 10 kHz
non spéci é 10 kHz - 35 kHz
Protection contre la surcharge : 1000 V ; impédance : 10 M
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC-890 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC-890 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 6,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info