536159
45
Zoom out
Zoom in
Previous page
1/84
Next page
126
Température
Plage Précision Résolution
-40 à +40 ºC ±(3 % + 20 digit)
0,1 ºC+40 à +400 ºC ±(2 % + 20 digit)
+400 à +1000 ºC ± 2,5 %
-40 à +32 ºF ±(2,5 % + 40 digit)
0,2 ºF+32 à +752 ºF ±(1,5 % + 40 digit)
+752 à +1832 ºF ± 2,5 %
Protection contre la surcharge : 1000 V
Test des diodes
Tension d’essai Résolution
3,1 V 0,0001 V
Protection contre la surcharge : 1000 V
Contrôleur acoustique de continuité
Résolution: 0,01
Protection contre la surcharge : 1000 V, <10 signal sonore constant
Test du ltre passe-bas
Plage Résolution Remarques
6 V 0,0001 V Signal de tension AC du ltre supérieure
à 1 kHz.
60 V 0,001 V
600 V 0,01 V
1000 V 0,1 V
47
2. INTENDED USE
Measuring and displaying electric parameters in the range of overvoltage category CAT IV up to
max. 600 V or CAT III up to max. 1000 V against ground potential, pursuant to EN 61010-1 and all
lower categories.
Measurement of direct and alternating voltage up to max. 1000 V
Measurement of direct and alternating currents up to max. 10 A
Frequency measuring up to 60 MHz
Measurement of capacities up to 60 mF
Measurement of resistances up to 60 M
Continuity test (<10 acoustic)
Diode test
Measurement of temperature from -40 to +1000 ºC
Display of duty cycle in % (10 – 90 %)
1 kHz low pass lter alternating voltage measurement
Comparison value measurement
Data memory and data logger for 1000 values with time stamp
Data transmission to a PC via optical interface
Date and time display
The measuring functions are selected using the rotary switch. The measuring range selection is
automatic for all measuring functions (except for diode and continuity test). Manual setting is possible
at any time.
The VC890 displays true RMS in both the direct and alternating voltage and current range.
For negative values, the polarity will automatically be displayed with the sign (-).
The two current measuring inputs are secured against overload with ceramic high-performance fuses.
The voltage in the current measuring circuit may not exceed 1000 V in CAT lll or 600 V in CAT IV.
A low impedance (Low Imp) function allows measurement with reduced internal resistance. This
suppresses phantom voltages which could appear in high-resistance measurements. Measurement
with reduced impedance is only permitted in measuring circuits up to max. 1000 V and only for max.
3 s. When the Low Imp button is pressed, a signal will sound and a warning indicator will be displayed.
The multimeter is powered by a standard 9 V alkaline or lithium monobloc battery. Operation is only
permitted with the speci ed battery type. An automatic power off prevents the battery from draining
prematurely if the device is not used for a period of time (settings: 5 min., 15 min., 30 min. or OFF;
see Chapter “19. Auto Power Off function”). The Auto Power Off function is switched off during data
transmission to a PC via optical interface.
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC-890 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC-890 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 6,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info