d) REL Function
The REL function allows a reference value measurement to avoid possible scatter displays or line loss as it occurs,
e.g., during impedance measurements. For this purpose, the current indicated value is set to zero. A new reference
value is set. Auto-range is deactivated.
Pressthe“REL”buttontoactivatethismeasuringfunction.Thedisplayindicates“Δ”.
Inordertoswitchoffthisfunction,pushthe“REL”buttonagainorchangethemeasurementfunction.
This additional function cannot be activated in the measuring function “Motor” and “Hz”.
e) Hz Function, frequency measurement (electrical)
The AC voltage and current measurement ranges are occupied with subfunctions for frequency measurement. These
measuring functions require a signal level of >30 Vrms and have a bandwidth of up to 400 Hz. They are therefore
suitable for mains voltage.
Tomeasurethefrequencyofthecurrentorvoltagesignal,pushthebutton“Hz”.Thedisplayshowsthefrequencyin
Hz.Toswitchthedisplay,pushthebutton“Hz”again.
f) HOLD Function
The Hold function keeps the currently indicated measured value in the displays to allow you to read or record it easily.
If you test live wires, make sure that this function is deactivated before the measurement starts.
Otherwise, the measurement will be incorrect!
This additional function cannot be activated in the measuring function “Motor”
ToswitchontheHoldfunction,pushthe“HOLD”button;asignalsoundconrmsthiscommandand“H”appearson
the display.
InordertoswitchofftheHoldfunction,pushthe“HOLD”buttonagainorchangethemeasurementfunction.
g) Display illumination
The multimeter automatically recognises the brightness in the environment via a light sensor and switches on display
lightingautomaticallywhentheDMMison.Thisautomaticfunctionisdisplayedbythesymbol“BL”.Itcanbedeacti-
vated via the lighting button and remains deactivated until switched off via the dial switch. This automatic function
is activated again at the next activation.
h) LED lamp
A white LED lamp (K) is integrated at the rear of the device. The lamp is switched on and off via the button with the
torch icon. Every push of a button will switch the lamp on or off again.
The lamp remains on until switched off manually via the button, until the meter is switched off via the dial switch (OFF)
or the device is deactivated automatically after approx. 15 minutes.
56


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC-450 E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC-450 E in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 9,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info