j) Capacity measuring
Make sure that all circuit parts, circuits and components and other objects of measurement are
disconnected from the voltage and discharged.
Always observe polarity with electrolyte capacitors.
- TurntheDMMonandselectmeasuringfunction“Capacity”
- PlugtheredmeasuringlineintotheΩmeasuringjack(E)
and the black measuring line into the COM measuring jack
(D).
Due to the sensitive measuring input, the display
mayshowavalueifthemeasuringlinesare“open”.
Bypressingthebutton“REL”,thedisplayissetto
“0”. The autorange feature is deactivated. This is
recommended for small capacities in the nF range.
- Connect the two measuring prods (red = plus/black = minus)
with the object to be measured (capacitator). After a short
time the display shows the capacity. Wait until the displayed
value has stabilised. This may take a few seconds for ca-
pacities of >40 µF.
- If“OL”(overload)appearsonthedisplay,youhaveexceed-
ed the measuring range.
- Remove the measuring lines from the object to be measured
after completion of the measurement and switch off the DMM.
k) Frequency measurement (electronic)
The DMM can be used to measure and indicate signal voltage frequencies from 600 Hz to 40 MHz. The maximum
input range is 30 Vrms. This measuring function is not suitable for mains voltage measurements. Please observe the
input values in the technical data.
Formainsvoltagemeasurements,usetheadditionalfunction“Hz”inthecorrespondingvoltageandcurrent
measurement ranges.
Proceed as follows to measure frequencies:
- TurntheDMMonandselectmeasuringfunction“Hz”.The
displayindicates“Hz”.
- Plug the red measuring line into the Hz measuring jack (E)
and the black measuring line into the COM measuring jack
(D).
- Connect the two measuring prods to the object to be meas-
ured in parallel (signal generator, circuit, etc.).
- The frequency and corresponding unit are displayed.
- Remove the measuring lines from the object to be meas-
ured after completion of the measurement and switch off the
DMM.
52


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Voltcraft VC-450 E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Voltcraft VC-450 E in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 9,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info