580333
15
Zoom out
Zoom in
Previous page
1/36
Next page
D-302989 15
4.4.19 Jam Detect
(Fig. 4.4, location 19). Here you determine whether
jamming (interfering transmissions, on the radio channel
used by the system) will be detected and reported or not.
If a jam detection option is selected, the system does not
allow arming under the relevant jamming conditions.
Jam Detection Options
Option Detection and Reporting when
UL (20/20)
(USA standard)
There is continuous 20 seconds of
jamming
EN (30/60)
(Europe standard)
There is an accumulated 30 seconds of
jamming within 60 sec.
class 6 (30/60)
(British standard)
Like EN (30/60) but the event will be
reported only if the jamming duration
exceeds 5 minutes.
Disabled (No jamming detection and reporting).
4.4.20 Latchkey
(Fig. 4.4, location 20). Here you determine whether the
system can be armed in the latchkey mode. If the system
is armed this way, a “latchkey” message will be sent to
specific telephones upon disarming by a “latchkey user”
(users 5-8 or keyfob transmitters 5-8). This mode is useful
when parents at work want to be informed of a child’s
return from school. The options are: Latchkey ON and
Latchkey OFF.
4.4.21 “Not Active”
(Fig. 4.4, location 21). Here you determine the time limit for
reception of signals from sensors used to monitor the
activity of sick, elderly or disabled people. If no sensor
detects and reports movement at least once within the
defined time limit, a “not-active” alert is initiated.
Options: 3, 6, 12, 24, 48, 72 hours and no act disable.
4.4.22 Back Light (Optional)
(Fig. 4.4, location 22). Here you determine whether the
keypad back lighting will remain on at all times or will turn
on when a key is pressed and turn off within 10 seconds if
no further keystrokes are sensed.
The two options are: always on and off after 10 s.
Note: Back Light can be used only if this option is
available on the purchased control panel.
4.4.23 Duress
(Fig. 4.4, loc. 23). A duress alarm (ambush) message can
be sent to the central station if the user is forced to disarm
the system under violence or menace. To initiate a duress
message, the user must disarm the system with the duress
code (2580 by default). Here you can change the code
digits or enter "0000" to disable the duress feature. The
system does not allow the user to program the duress
code saved in this memory location as an existing user
code.
4.4.24 Piezo Siren
(Fig. 4.4, location 24). Here you determine whether the
internal siren will sound or remain silent upon alarm
(according to the user preference). Options: piezo siren
on, piezo siren off.
4.4.25 Reset Option
(Fig. 4.4, location 25). (Not applicable in the USA)
Here you determine whether the system can be rearmed
(after an event) by the user or only by the installer.
Options: user reset or engineer reset.
If Engineer Reset is selected, the system can be rearmed
only by the installer
; by entering and exiting the installer
menu, by entering and exiting the event log (see section 7),
or by remote telephone. To perform Engineer Reset via the
telephone, establish communication with the
PowerMaxExpress (see user guide, par. 6.3A, steps 1-5)
and continue as follows:
a. [*], [installer code], [#]
b. Wait for 2 beeps
c. [*], [1], [#]
d. [*], [99], [#]
4.4.26 Tamper Option
(Fig. 4.4, location 26). Here you determine whether zone
tamper will be reported or ignored. Available options are:
zone tamper ON and zone tamper OFF.
Note: To comply with EN requirements, "zone tamper ON"
must be selected.
4.4.27 Siren On Line
(Fig. 4.4, location 27).
Here you determine whether the
siren will be activated or not when the telephone line fails
during system armed state. Available options are: enable
on fail, disable on fail.
4.4.28 Memory Prompt
(Fig. 4.4, location 28). Here you determine whether the user
will receive indication that an alarm has been activated.
Available options are: enable and disable.
4.4.29 Disarm Option
(Fig. 4.4, location 29).
Here you determine when it is possible
to disarm the system:
A. Any time.
B. In AWAY mode, during entry delay, by using the
PowerMaxExpress keypad or wireless sensor (keyfob).
C. In AWAY mode, during entry delay, by using a wireless
device (keyfob) only (this is set as a default in UK to
comply with DD243).
D. During entry delay, or by using the PowerMaxExpress
keypad in AWAY mode.
Options: any time, on entry all, on entry wireless, or
entry + away kp.
4.4.30 Bell/Rep. Option
(Fig. 4.4, location 30). Here you determine whether an
alarm will be initiated (siren / report) when there is a
supervision / jamming failure during AWAY arming state.
Available options are: EN standard and other. When "EN
standard" is selected, if there is supervision / jamming
failure during AWAY arming, the siren is activated and the
events are reported as tamper events. When "Other" is
selected, there is no such activity during AWAY arming.
4.4.31 Low-Bat Ack
(Fig. 4.4, location 31). Here you determine whether the user
will hear or will not hear low battery sound when he tries to
disarm the system with a keyfob whose battery voltage is
low. Available options are: keyfob L-B on (the user has to
acknowledge the keyfob low battery message) or keyfob
L-B off (the user does not have to acknowledge the keyfob
low battery message).
4.4.32 Screen Saver
(Fig. 4.4, location 32). Here you can determine that if no
key is pressed during more than 30 seconds, the display
will be “PowerMax” (to prevent possible intruder of
knowing the system status). You can determine that
normal display will return after pressing the
button followed by entering user code (Refresh by Code)
or after pressing any key (Refresh by Key).
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Visonic PowerMax Express at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Visonic PowerMax Express in the language / languages: English as an attachment in your email.

The manual is 3,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Visonic PowerMax Express

Visonic PowerMax Express User Manual - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info