EVENT REPORTING & CONTROL BY TELEPHONE AND SMS
D-304829 PowerMaster-10/30 G2 User's Guide 49
7. Event Reporting and Control by Telephone and SMS
Event notifications by Telephone
The PowerMaster can be programmed for selective notification of event messages to private telephone
subscribers See Chapter 6, B.12 Programming Private Phone, Email, MMS and SMS Reporting. Messages
are divided by type into the following groups:
Group Events Reported
1 Fire, Burglary, Panic, Tamper
2* Arming AWAY, Arming HOME, Disarming
3 No-activity, Emergency, Latchkey, Gas, Flood, Temperature
4* Low-battery AC failure
* PowerMaster-30 G2 only
Note: For UL installations, SMS is a supplementary feature.
PowerMaster-10 G2 control panels
In case of alarm the following voice signal will be sent to private telephones upon event reporting:
* FIRE: ON - ON - ON - pause....
(- - - - - -
......).
** BURGLAR: ON continuously ( ...)
*** EMERGENCY: 2-tone siren; like an ambulance.
To stop the alarm notification – press the "2" key on your telephone keyboard. The alarm sound will stop
immediately.
The called party must acknowledge the message (as explained later on). However, if there is no response the
message will be repeated as many times as possible within a 45-second time limit. When the 45 seconds are
up, the PowerMaster will disengage the line and call the next private telephone number on its list.
The called party must acknowledge the message by pressing the "2" key on the telephone keypad. As a result,
the PowerMaster may continue to notify the next programmed telephone number, or if so programmed, consider
the event as reported - see Chapter – 6, B.11.
PowerMaster-30 G2 control panels
When the called party answers a call initiated by the PowerMaster, he will hear a verbal message composed of the
“house identity” and the type of event that occurred. For example, once smoke is detected in the Smith residence,
the message will be:
[The Smith Residence - Fire Alarm].
If a person under surveillance in the Watkins residence has been inactive, the message will be:
[The Watkins Residence - No Activity].
The called party must acknowledge the message (as explained later on), but if he does not respond, the
message will be transmitted repeatedly as many times as possible within a 45-second time limit. When the 45
seconds are up, the PowerMaster will disengage the line and call the next private telephone number on its list.
The called party can acknowledge the message by pressing a key on the telephone keypad, as follows.
Command Key
Acknowledge only: The PowerMaster disengages the line and considers the event duly reported.
2
Acknowledge and listen-in: The protected site is “bugged” for sound for 50 seconds. The called party
may prolong the listening session by pressing [3] again before the PowerMaster disengages the line, or
by pressing [1] to speak.
3
Acknowledge and speak out: The called party may speak for 50 seconds to whoever is in the
protected site. The called party may prolong the “speak out” session by pressing [1] again before the
PowerMaster disengages the line, or by pressing [3] to listen.
1
Acknowledge and 2-way conversation: You and the called party can speak and listen without any
necessity to switch the system from "listen-in" to "speak-out"
and
vice
versa for 50 sec. (extendable).
6
Acknowledge and request a status report: The PowerMaster will issue a verbal report of system
status. For example:
[Disarm - ready to arm] or
[Disarm - back door open] or
[Disarm - alarm in memory].
9
50


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Visonic PowerMaster-10-30 G2 Version 18 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Visonic PowerMaster-10-30 G2 Version 18 in the language / languages: English as an attachment in your email.

The manual is 2,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Visonic PowerMaster-10-30 G2 Version 18

Visonic PowerMaster-10-30 G2 Version 18 Installation Guide - Dutch - 112 pages

Visonic PowerMaster-10-30 G2 Version 18 User Manual - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info