Ending "Standby mode"
Select a different operating program for ventilation, or
a comfort or energy saving function.
Stopping ventilation to change the filters
To change the filter, open the ventilation unit.
!Please note
Operating the open ventilation unit without filters
will lead to dust being deposited in the unit.
These dust deposits can result in malfunctions.
Switch off the ventilation unit before opening it,
as described below.
Vitovent 200-C, Vitovent 200-W, Vitovent 300-C
and Vitovent 300-W:
Pull the power supply plug of the ventilation unit from
its socket: See page 69 onwards.
Vitovent 300-F:
Turn off the ventilation unit at the ON/OFF switch:
See page 75.
Displays
After switching off the ventilation unit, the symbol
will be displayed on the heat pump control unit.
The message "EF Modbus subscriber" may
appear on the display. This message will disappear
once you restart the ventilation unit.
Setting the operating program for ventilation
In the operating program for ventilation you set
whether mechanical ventilation is enabled or not.
For an overview of the operating programs, see
page 22.
1. Extended menu:
2. "Ventilation"
3. "Operating program"
4. E.g. "Ventilation program"
Ventilation without heat recovery
For ventilation without heat recovery, the bypass on
the ventilation unit is active. Fresh outdoor air is sup-
plied directly to the home without passing through the
heat exchanger.
This allows your home to be passively heated or
cooled by the supply air, depending on the tempera-
tures inside and outside the building.
Conditions for switching on passive heating and pas-
sive cooling: See page 95.
Setting the room temperature for ventilation
As soon as the room temperature exceeds the set
value specified here, ventilation without heat recovery
can take place.
Mechanical ventilation
Stopping ventilation (cont.)
5817913
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann VITOTRONIC 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann VITOTRONIC 200 in the language / languages: English as an attachment in your email.

The manual is 3.87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann VITOTRONIC 200

Viessmann VITOTRONIC 200 User Manual - German - 112 pages

Viessmann VITOTRONIC 200 User Manual - Dutch - 112 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info