813781
35
Zoom out
Zoom in
Previous page
1/112
Next page
35
Your DHW is always heated to this temperature when
a time phase with the operating status "Standard" is
active in the time program.
Setting the time program for DHW heating: See
page 35.
Factory setting: 50 °C
1. Extended menu:
2. "DHW"
3. "Set DHW temperature"
4. Set the required value.
Setting the higher DHW temperature
The DHW will be heated to the higher DHW tempera-
ture under the following circumstances:
In the time program for DHW heating, a time phase
for the "Temp. 2" operating status is enabled: See
page 36.
You have selected once-only DHW heating: See
page 37.
You have selected manual mode: See page 58.
Factory setting: 60 °C
1. Extended menu:
2. "DHW"
3. "Set DHW temperature 2"
4. Set the required value.
Note
Where necessary, enable the electric booster heater in
order to achieve the required DHW temperature: See
page 39.
Setting the operating program for DHW heating
In the for DHW heating operating program you set
whether DHW heating is enabled or not.
For an overview of the operating programs, see
page 21.
For the preferred heating/cooling circuit
1. Standard menu:
/ for the operating program:
e.g. "Only DHW"
2. OK to confirm
For all heating/cooling circuits
1. Extended menu:
2. "Heating" or "Heating/cooling"
3. If applicable, use / to select the required heating/
cooling circuit
4. "Operating program"
5. E.g. "Only DHW".
Setting the time program for DHW heating
In the time program for DHW heating, you set the time
phases in which your DHW is heated and to what tem-
peratures.
To do so, select an operating status for each time
phase: See chapter "Operating status for DHW heat-
ing".
Factory setting: one time phase from 00:00 to 24:00 h
for every day of the week with the "Top" operating sta-
tus
1. Extended menu:
2. "DHW"
3. "Time program DHW"
4. Set the required time phases and operating status.
To see how to set a time program: See page 23.
DHW heating
Setting the standard DHW temperature
5817913
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann VITOTRONIC 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann VITOTRONIC 200 in the language / languages: English as an attachment in your email.

The manual is 3.87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann VITOTRONIC 200

Viessmann VITOTRONIC 200 User Manual - German - 112 pages

Viessmann VITOTRONIC 200 User Manual - Dutch - 112 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info