813833
9
Zoom out
Zoom in
Previous page
1/112
Next page
9
Intended use presupposes that a fixed installation in
conjunction with permissible, system-specific compo-
nents has been carried out.
Commercial or industrial usage for a purpose other
than central heating/cooling or DHW heating shall be
deemed inappropriate.
Incorrect usage or operation of the appliance (e.g. the
appliance being opened by the system user) is prohibi-
ted and will result in an exclusion of liability. Incorrect
usage also occurs if the components in the heating
system are modified from their intended function.
Note
The appliance is intended exclusively for domestic or
semi-domestic use, i.e. even users who have not had
any instruction are able to operate the appliance
safely.
Product information
Heat pump control unit
The Vitotronic 200 heat pump control unit, type WO1C
controls all functions of your heating system with heat
pump and mechanical ventilation.
The heat pump control unit may be installed in different
locations depending on the type of heat pump: See
page 15.
At the front of the heat pump
At the top of the heat pump
In a separate enclosure on the wall
Heat pump types
Air/water heat pumps
Air/water heat pumps utilise energy from the ambient
air to generate heat. To achieve this, a fan draws the
ambient air through a heat exchanger (evaporator). In
the evaporator, the thermal energy from this ambient
air is transferred to the refrigerant circuit. Here, the
temperatures necessary for central heating and DHW
heating are generated. The refrigerant circuit is driven
by the compressor.
To provide central cooling, the refrigerant circuit oper-
ates in reverse mode. Heat is extracted from your
rooms and transferred to the ambient air via the evap-
orator.
Note
Air/water heat pumps can have two stages. Two-stage
air/water heat pumps have 2 compressors which can
be activated individually or simultaneously subject to
the requested heating output.
Air/water heat pumps are available in the following
casing/installation versions:
Heat pump for indoor installation
All of the heat pump components, including the heat
pump control unit, are housed in a casing and instal-
led inside the building. The outdoor air is brought to
the heat pump and returned to the outside via an air
duct system.
Heat pump for outdoor installation
All of the heat pump components, except for the heat
pump control unit, are housed in a casing that is
installed outside the building. The heat pump control
unit is mounted inside the building. The heat pump is
hydraulically connected to the heating system of the
building.
Air/water heat pumps with separate indoor/outdoor
units
The outdoor unit is installed outside the building or fit-
ted to the outside of the building. Heat is obtained from
the ambient air in the outdoor unit.
The indoor unit, including the heat pump control unit, is
installed inside the building and transfers the heat to
the heating system.
The indoor and outdoor units are connected to each
other hydraulically and electrically.
Introductory information
Intended use (cont.)
5817913
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann Vitotronic 200 - WO1C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann Vitotronic 200 - WO1C in the language / languages: English as an attachment in your email.

The manual is 3.87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann Vitotronic 200 - WO1C

Viessmann Vitotronic 200 - WO1C User Manual - German - 112 pages

Viessmann Vitotronic 200 - WO1C User Manual - Dutch - 112 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info