You can select the following tempera-
tures:
Room temperature "Comfort" (stand-
ard room temperature)
Setting in the delivered condition:
21 °C
Setting range: 10 to 40 °C
Room temperature "Eco"
Setting in the delivered condition:
19 °C
Setting range: 10 to 40 °C
Reduced room temperature
"Reduced"
Setting in the delivered condition:
16 °C
Setting range: 10 to 40 °C
01. Open the flap.
02. Press twice.
03. Select "Settings" with / .
04. Confirm with OK.
05. Select "Tmp settings" with / .
06. Confirm with OK.
07. Set the required temperature for
"Comfort" with / .
08. Confirm with OK.
09. Set the required temperature for
"Eco" with / .
10. Confirm with OK.
11. Set the required temperature for
"Reduced" with / .
12. Confirm with OK.
Setting an individual time program
Setting time phases
In the preset time programs "Prog 1" to
"Prog 3", the day is split into 6 time pha-
ses.
However, you can also split the day into
less than six time phases:
For time phase 1, always select "Time
ph. 1".
and
For the last time phase, always select
"Time ph. 6".
Example:
In "Prog. 3", you only want to enable
three time phases. "Comfort" from
06:00 h to 10:00 h; "Eco" from 10:00 h
to 22:00 h; and "Reduced" from 22:00 h
to 06:00 h.
Select "Time ph. 1", "Time ph. 2" and
"Time ph. 6".
Time phases 3, 4 and 5 are automatically
disabled.
For every enabled time phase, the fol-
lowing must be entered:
Start time
Stop time
Temperature ("Comfort", "Eco",
"Reduced")
Central heating
Setting a permanent room temperature
5592 620 GB
13


Need help? Post your question in this forum.

Forumrules
1

Forum

viessmann-vitotrol-100---utdb-rf2

Reset search

  • Thermostat won’t drop below 18 have tried reset but no change Submitted on 24-10-2022 at 12:52

    Reply Report abuse
  • I am trying to change the on / off time settings for the heating but it won't save the changes Submitted on 6-12-2021 at 15:39

    Reply Report abuse
  • how can i alter the control to stop the heating system working every time i put the boiler on? i only switch it on for hot water to save money, but the radiators come on too? i seem not to be able to alter the manual setting....
    any advice would be very appreciated.
    thank you Submitted on 19-8-2021 at 18:43

    Reply Report abuse
    • Hi, Having the same problem with the stat resetting at random times and the heating coming on. New batteries have been installed. Answered on 1-9-2022 at 14:45

      Vote up Report abuse
  • heating control set for prog 1 batteries strong time set correc t heating does not come on at correct times Submitted on 23-10-2018 at 21:37

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann VITOTROL 100 - UTDB-RF2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann VITOTROL 100 - UTDB-RF2 in the language / languages: English as an attachment in your email.

The manual is 0,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann VITOTROL 100 - UTDB-RF2

Viessmann VITOTROL 100 - UTDB-RF2 Installation Guide - English - 16 pages

Viessmann VITOTROL 100 - UTDB-RF2 Installation Guide - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info