Commissioning steps
Inspection steps
Maintenance steps Page
! ! !
01. Pivoting down the control unit for commissioning
and maintenance work
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23
02. Filling the heating system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23
03. Venting the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
04. Venting the heating system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
05. Filling the solar circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26
06. Checking the power supply connection
07. Setting the time and date (if required) . . . . . . . . . . . . . . . . . . . . . . . . . .
29
08. Selecting the language (if required) only for
weather-compensated control units
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29
09. Checking the gas type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30
10. Gas type conversion (only for operation with LPG) .
31
11. Function sequence and possible faults . . . . . . . . . . . . . . . . . . . . . . . .
31
12. Checking the static and supply pressure . . . . . . . . . . . . . . . . . . . .
33
13. Setting the maximum output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
35
14. Checking all connections on the heating water
side and DHW side for leaks
15. Checking the burner (recording values on
page 143 of the commissioning/service report)
16. Checking the balanced flue system for soundness
(annular gap check)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
35
17. Removing the burner and checking the burner
gasket (replace gasket every two years)
. . . . . . . . . . . . . . . . . . . . . .
36
18. Checking the burner gauze assembly . . . . . . . . . . . . . . . . . . . . . . . . . . .
37
19. Checking and adjusting the ignition and ionisation
electrodes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
38
20. Cleaning the combustion chamber/heating
surfaces and fitting the burner
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
Steps - commissioning, inspection and maintenance
21
Commissioning, inspection, maintenance
5592 883 GB
Service
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann VITODENS 343-F type WS4A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann VITODENS 343-F type WS4A in the language / languages: English as an attachment in your email.

The manual is 8,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann VITODENS 343-F type WS4A

Viessmann VITODENS 343-F type WS4A Installation Guide - German - 148 pages

Viessmann VITODENS 343-F type WS4A User Manual - Dutch - 28 pages

Viessmann VITODENS 343-F type WS4A Installation Guide - Dutch - 148 pages

Viessmann VITODENS 343-F type WS4A Installation Guide - Dutch - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info