Low voltage plugs
! Outside temperature sensor
(only for weather-compensated
control units).
Terminals X3.1 - X3.2.
Installation:
&
North or north-western wall,
2 to 2.5 m above ground level;
in multi-storey buildings, in the
upper half of the second floor
&
Not above windows, doors or
ventilation outlets
&
Not immediately below balco-
nies or gutters
&
Never render over
&
2-core lead, max. 35 m length
with a cross-section of
1.5 mm
2
? Flow temperature sensor for low
loss header (accessories)
Terminals X3.4 - X3.5.
& Solar temperature sensor
Terminals X3.8 - X3.9.
NOTE: If no solar panels are
fitted to the appliance the solar
sensor has to be connected
otherwise the appliance is going
into an error code. Also switch
relay 1 off (see page 64 Manual
mode 0).
aVG KM BUS subscriber (acces-
sories)
Terminals X3.6 - X3.7.
&
Vitotrol 200 or 300 remote con-
trol
&
Vitocom 100
&
Extension kit for a heating cir-
cuit with mixer
&
Vitosolic
&
External extension H1 or H2
Refit the cover to the wiring chamber
(see page 18).
Electrical connections (cont.)
20
Installation sequence
5592 883 GB
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann VITODENS 343-F type WS4A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann VITODENS 343-F type WS4A in the language / languages: English as an attachment in your email.

The manual is 8,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Viessmann VITODENS 343-F type WS4A

Viessmann VITODENS 343-F type WS4A Installation Guide - German - 148 pages

Viessmann VITODENS 343-F type WS4A User Manual - Dutch - 28 pages

Viessmann VITODENS 343-F type WS4A Installation Guide - Dutch - 148 pages

Viessmann VITODENS 343-F type WS4A Installation Guide - Dutch - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info