EN NL FR DE ES SE Appendix
Red LED On or blinking
The inverter did shut down because of a protection. It will
no longer automatically restart. The red LED indicates the
reason for shutdown. Remove the cause and then restart
the inverter by switching it Off, and then back On.
Red LED
Definition
Trouble shooting
●●●●●●●● Solid on
Overload
Reduce load
●●●●----
Slow
blink
Low batt.
Recharge or replace battery
Check DC cable connections
Check cable cross section as it may be insufficient.
See section 4.2 Protections and automatic restarts for
manual and automatic restart behavior.
----
Fast
blink
High batt.
Reduce DC input voltage, check for faulty charger
------
Double
pulse
High temp.
Reduce load and/or move inverter to better ventilated area
------
Fast
single pulse
High DC ripple
Check DC cable connections and cable cross section.
3.4 Protections and automatic restarts
Overload
Some loads like motors or pumps draw large inrush currents in a start-up situation. In
such circumstances, it is possible that the start-up current exceeds the over current trip
level of the inverter. In this case the output voltage will quickly decrease to limit the output
current of the inverter. If the over current trip level is continuously exceeded, the inverter
will shut down: wait 30 seconds and then restart.
After three restarts followed by another overload within 30 seconds of restarting, the inverter
will shutdown and remain off. The LEDs will signal shutdown due to overload. To restart the
inverter, switch it Off, then On.
Low battery voltage (adjustable)
The inverter will shut down when the DC input voltage drops below the low battery shutdown
level. After a minimum delay of 30 seconds, the inverter will restart if the voltages rise above
the low battery restart level.
After three restarts followed by a low battery shutdown within 30 seconds of restarting, the
inverter will shutdown and stop retrying. The LEDs will signal low battery shutdown. To restart
the inverter, switch it Off, and then On, or recharge the battery: as soon as the battery has
risen and then stays above the Charge detect level for 30 seconds, it will switch on.
See the Technical Data table for default low battery shutdown and restart levels. They can be
changed with the VictronConnect App.
High battery voltage
Reduce DC input voltage and/or check for a faulty battery- or solar-charger in the system.
After shutting down due to a high battery voltage, the inverter will first wait 30 seconds and
then retry operation as soon as the battery voltage has dropped to acceptable level. The
inverter will not stay off after multiple retries.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Phoenix 12 2000 Omvormer at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Phoenix 12 2000 Omvormer in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 0.74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info