2. DESCRIPTION
2.1 General
Bluetooth built-in: fully configurable with a tablet or smartphone
Low battery voltage alarm trip and reset levels
Low battery voltage cut-off and restart levels
Dynamic cut-off: load dependent cut-off level
Output voltage: 210 - 245V
Frequency: 50 Hz or 60 Hz
ECO mode on/off and ECO mode sense level
Alarm relay
Monitoring:
In- and output voltage, % load and alarms
VE.Direct communication port
The VE.Direct port can be connected to a computer (VE.Direct to USB interface cable
needed) to configure and monitor the same parameters.
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many
years.
The inverters are short circuit proof and protected against overheating, whether due to
overload or high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric
tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a
preset value (min load: 15W). Once in standby the inverter will switch on for a short period
(adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will
remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, between battery plus and
the left hand contact of the two pole connector or between battery minus and the right hand
contact of the two pole connector
LED diagnosis
Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax
features a very short switchover time (less than 20 milliseconds) so that computers and other
electronic equipment will continue to operate without disruption. Alternatively use a MultiPlus
with built-in transfer switch.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Phoenix 12 2000 Omvormer at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Phoenix 12 2000 Omvormer in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 0.74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info