785524
149
Zoom out
Zoom in
Previous page
1/164
Next page
EN NL FR DE ES SE Appendix
EN:
A
AC input 16 A. Left to right: PE (earth/ground), L (phase), N (neutral).
AC input 50 A. Left to right: L (phase), N (neutral), PE (earth/ground).
B
2x RJ45 connector for remote control and/or parallel / three-phase operation
C
Load connection. AC out1. Left to right: L (phase), N (neutral), PE (earth/ground).
D
Load connection. AC out2.
16 A Left to right: N (neutral), L (phase), PE (earth/ground).
50 A Left to right: PE (earth/ground), L (phase), N (neutral).
E
Terminals for 16 A: (left to right)
Voltage sense
Aux input 1
Starter battery plus + (starter battery minus must be connected to service battery minus)
GND-relay
Temperature sensor
Terminals for 50 A: (left to right)
Temperature sensor
Aux input 1
Aux input 2
GND-relay
Starter battery plus + (starter battery minus must be connected to service battery minus)
Programmable relay contacts K1
Programmable relay contacts K2
Voltage sense
F
Double M8 battery minus connection.
G
Double M8 battery positive connection.
H
Connector for remote switch:
Short left and middle terminal to switch “on”.
Short right and middle terminal to switch to “charger only”.
I
Alarm contact: (left to right) NC, NO, COM.
K
Pushbuttons for set-up mode.
L
Primary ground connection M8 (PE).
M
Dipswitches DS1- DS8 for set-up mode.
N
Slide switches, factory setting 16 A: SW1= right (off) position, SW2 = right (off) position.
SW1: No application. To be used for future features.
SW2: INT(R) = internal GND relay selected, EXT(L) = external GND relay selected (to connect ext
GND relay: see E).
Slide switches, factory setting 50 A: SW1= down (off) position, SW2 = down (off) position.
SW1: down (off) = internal GND relay selected, up (on) = external GND relay selected (to connect
ext GND relay: see E).
SW2: No application. To be used for future features.
NL:
A
Wisselspanning ingang AC-in 16 A. Van links naar rechts: PE (aarde), L (fase), N (nul).
Wisselspanning ingang AC-in 50 A: Van links naar rechts: L (fase), N (nul), GROUND (aarde).
B
2x RJ45 connector voor afstandbedieningspaneel en/of parallel en 3-fase bedrijf.
C
Wisselspanning uitgang AC-out-1. Van links naar rechts: L (fase), N (nul), PE (aarde).
D
Wisselspanning uitgang AC-out-2 16 A. Van links naar rechts: N (nul), L (fase), PE (aarde).
Wisselspanning uitgang AC-out-2 50 A. Van links naar rechts: PE (aarde), L (fase), N (nul).
E
Aansluitklemmen voor 16 A: (van links naar rechts)
Voltage sense
Aux ingang 1
Start accu plus + (de min van start accu moet vebonden zijn met de min van de service accu)
GND-relais
Temperature sensor
Aansluitklemmen voor 50 A: (van links naar rechts)
Temperature sensor
Aux ingang 1
Aux ingang 2
GND-relais
Start accu plus + (de min van start accu moet verbonden zijn met de min van de service accu)
Relais contacten K1
Relais contacten K2
Voltage sense
F
Dubbele M8 accu min aansluiting.
G
Dubbele M8 accu plus aansluiting.
H
Aansluitklemmen voor afstandbedieningsschakelaar.
Verbind de linker klem en de middelste klem om de MultiPlus aan te schakelen.
Verbind de rechter klem en de middelste klem voor ‘alleen laden’.
I
Alarm contact: (van links naar rechts) NC, NO, COM.
149


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron MultiPlus 12 3000 120-16 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron MultiPlus 12 3000 120-16 in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 2.06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info