Figure 2. Connection sequence when connecting two Lynx modules
Lynx module
M8 bolt
M8 Spring washer
M8 Washer
Lynx module
Correct placement of the M8 washer, spring washer and nut.
6.2. Electrical connections
6.2.1. Connect DC wires
This chapter might not apply if the Lynx module is connected to other Lynx modules, like can be the case for the Lynx Smart BMS
or the Lynx Shunt VE.Can.
For all DC connections the following applies:
All cables and wires connected to the Lynx module need to have been fitted with M8 cable lugs.
Pay attention to the correct placement of the cable lug, washer, spring washer and nut on each bolt when attaching the cable to
the bolt.
Tighten the nuts with a torque moment of 14Nm.
Figure 3. Correct mounting sequence DC wires
M8 bolt
M8 Spring washer
M8 Washer
Cable lug
Lynx module
Correct placement of the M8 Cable lug, washer, spring washer and nut
6.2.2. Connect RJ11 cable(s)
These instructions only apply if the system contains Lynx distributor(s) together with a Lynx Smart BMS or a Lynx Shunt VE.Can.
There are two RJ11 connectors in each Lynx Distributor, one on the left and one on the right. See below drawing.
RJ11 connector
RJ11 connector
RJ11 connector
Recess
RJ11 connector
Recess
RJ11 connector RJ11 connector
Recess Recess
Locations of the RJ11 connectors and RJ11 cable recesses on the Lynx Distributor, Lynx Smart BMS and the Lynx VE.Can
To connect the RJ11 cables between the various Lynx modules do the following:
Plug one side of the RJ11 cable in the RJ11 connector of the Lynx distributor, with the retainer clip of the RJ11 connector facing
away from you.
Feed the RJ11 cable through the recess at the bottom of the Lynx Distributor, see above picture.
To connect to a Lynx Smart BMS, plug the RJ11 cable into the RJ11 connector at the bottom of the Lynx Smart BMS.
Lynx Smart BMS
Page 14 Installation
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Lynx Smart BMS 500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Lynx Smart BMS 500 in the language / languages: English as an attachment in your email.

The manual is 3.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info