5. Operation
On/Off/Charger Only Switch
The switch is located on the underside to the bottom right of the product.
The switch has three positions. The centre position 0 is Off. The I position is On, and the II position is Charger Only.
When switched to 'I / On' (rocked towards the front of the unit), the product will come into operation and the inverter is
fully functional.
If an AC voltage is connected to the 'AC in' terminal, it will be switched through to the 'AC out' terminal, if within
specifications. The inverter will switch off, and the charger commences charging. 'Bulk', 'Absorption' or 'Float' will display,
depending on the charger mode.
If the voltage at the 'AC-in' terminal is rejected, the inverter will switch on.
When the switch is switched to 'II / Charger Only', only the battery charger of the Multi will operate (if mains voltage is
present). In this mode input voltage also is switched through to the 'AC out' terminal.
NOTE: When only the charger function is required, ensure that the switch is switched to 'II / Charger Only'. This prevents
the inverter from being switched on if the mains voltage is lost, thus preventing your batteries from running flat.
6. GX LCD Interface
The display screen will present useful information about your system.
6.1 On/off behaviour
When the product is switched off with the physical switch on the device or with the Remote On/Off terminals, then the GX
card is off as well. If you switch the product remotely, using a Digital Multi Control, then the GX card will remain powered.
Also when switching the inverter/charger off from within the GX menus, the GX card will remain powered.
Lastly, when the inverter/charger switches itself off due to an alarm, such as low battery or overtemperature, then the GX
card will remain powered and functional as well.
6.2 Push button behaviour
When the GX Card is on, pushing the button beside the screen will activate the backlight. The backlight will turn itself off
after 5 minutes.
Once the backlight has been activated, pushing the button again will cycle through the available display options. Some
options will be displayed automatically, and others require a button push to display.
6.3 Information displayed
Solar Power, Voltage and Charge state (if connected)
ESS/DVCC reason codes (if active)
Solar Daily Yield
Inverter/charger charge state (eg Bulk, ESS)
Battery State of Charge, Power and Voltage
Network IP Address and Connection Type (if connected).
AC input and output Power
In a system with more than one phase, there will be additional AC input and output information available, eg
Phase 1 AC input Voltage and Power.
Phase 1 AC output Voltage and Power.
Phase 2 AC input Voltage and Power.
Phase 2 AC output Voltage and Power.
Phase 3 AC input Voltage and Power.
Phase 3 AC output Voltage and Power.
6.4 Error Code Display
If there is an error with the system, the error code will be displayed on the screen. The screen will display VE.Bus error
code numbers, and MPPT error codes (if connected).
Basic information about the VE.Bus Error codes are in the Error Indications section.
For further details about the error codes please see:
VE.Bus Error Codes
MPPT Error Codes
The error will display until it is cleared.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron EasySolar-II 48 3000 35-32 MPPT 250 70 GX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron EasySolar-II 48 3000 35-32 MPPT 250 70 GX in the language / languages: English, German, Dutch, French, Italian, Swedish, Spanish as an attachment in your email.

The manual is 2.84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info