Check 'Last contact'. If this shows dashes, the GX device has not been able to contact the VRM Portal since power up. If it shows
a time, but still an error is shown, then the GX device has been able to send data, but has since lost contact.
The 'Buffered items' indicates the number of logs that it has stored to send later. If this is larger than 0, it means that the Cerbo
GX can not connect to the VRM Portal. All data is sent using the First in First out principle: the VRM Portal will only show the most
up to date information after all old data has been sent.
9.5. Analysing data offline, without VRM
In certain cases, for example for very remote sites where there is no internet available, it can be useful to be able to analyse the
data without first having to upload it to the VRM Portal.
1. Install VictronConnect on a Windows or Apple laptop
2. Insert the storage device containing the log file(s)In Victron
3. Connect, use the GX Log Converter feature to convert them to Excel sheets.
9.6. Remote Console on VRM - Trouble shooting
Follow these steps to trouble shoot Remote Console on VRM
1. Make sure that Logging to the VRM portal works, see chapter 5.4. Without this; Remote Console on VRM will not work.
2. After enabling the Remote Console feature, make sure to set (or disable) the password.
3. Also make sure to restart the Cerbo GX after setting (or disabling) the password.
4. Make sure to update the Cerbo GX to the latest firmware version. The last stability improvement for Remote Console was
made in version v2.30.
5. After the restart, check the Remote Console on VRM status shows online or a port number. In case it says offline, or port
number 0, the Cerbo GX was unable to connect to the Remote Console server. This is normally caused by a (company) fire-
wall, blocking the connection. The solution is then to configure an exception rules in the firewall.
6. -Verify that your web browser, on which you're using VRM, can access both of below URLs. Click both of the links, to check
them. Note that seeing an Error means that all is OK. The good error is 'Error response, Error code 405, Method Not Allowed'.
If you get a timeout or another (browser) error, there may be a firewall blocking the connection. https://vncrelay.victronener-
gy.com & https://vncrelay2.victronenergy.com/
Technical background
To have Remote Console on VRM working, your web browser and the GX Device need to have a connection between them. This
connection is designed such that it doesn't need any special configuration or opening up of firewalls in almost all situations. The
0.1% of situations where it doesn't work out of the box are, for example, large corporate networks with special security, or long
range expensive satellite or radio supported networks, such as seen in rural areas of Africa and other remote areas.
When Remote Console on VRM is enabled, the GX Device will open and maintain a connection to any of the servers pointed to
by supporthosts.victronenergy.com. Which currently resolves to two IP addresses (84.22.107.120 and 84.22.108.49), and likely
more in the future. The technology used is SSH, and it will try to connect using port 22, 80 and 443, only one of them needs to
work. The reason for it to try all three is that on most networks at least one of them will be allowed by the local firewall.
Once connected to one the the supporthost servers, that reverse SSH tunnel is waiting to be connected from someone needing
the connection. Which can be your browser, or a Victron engineer since this same technology is used for the Remote Support
functionality; for more information see above.
Cerbo GX Manual
47
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Cebro GX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Cebro GX in the language / languages: English as an attachment in your email.

The manual is 5.1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info