Procedimiento de instalación (ver figura 3)
- Conecte los cables de entrada marrones y azules al neutro y a la fase de la entrada AC-in-1.
- Quattro: conecte los cables de salida marrones y azules al neutro y a la fase de la entrada AC-in-2.
MultiPlus: no hay entrada AC-in-2 disponible. Por favor corte los cables AC2 cerca del AC Detector
Figura 3: Conexión del AC Detector
- Utilice el cable corto UTP RJ45 para conectar el AC Detector a una de las dos las tomas VE.Bus del MultiPlus o
Quattro (ver figura 4).
- Conecte el BMS VE.Bus al AC Detector con un cable UTP (no incluido).
- Debe haber un panel Digital Multi Control conectado al BMS VE.Bus. No conecte un panel Digital Multi Control
directamente a un Multi o Quattro (las señales del panel de control pueden entrar en conflicto con las señales del
BMS VE.Bus).
- El panel ColorControl debe estar conectado directamente al Multi o Quattro.
Figura 4: Conexiones VE.Bus
4.2 Cableado del sistema: ver ejemplos de sistemas abajo
No conecte al positivo de la batería durante esta etapa (como alternativa: no inserte el fusible o fusibles de la batería).
Importante:
- El cable UTP del inversor o inversor/cargador también conecta el polo negativo de la batería al BMS.
En este caso, con el fin de evitar bucles a tierra, no conecte el conector negativo de la batería del BMS.
- Conecte el positivo de la alimentación del BMS VE.Bus al positivo del sistema. Un interruptor on/off en el cable
positivo de la alimentación del sistema desactivará el sistema cuando se abra.
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Battery Management System VE.Bus BMS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Battery Management System VE.Bus BMS in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 4.24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info