484572
38
Zoom out
Zoom in
Previous page
1/74
Next page
32
PID Operation And Adjustment
The PID has various settings and functions that can be changed by the user. This section leads you through
the various settings, explaining their function as well as giving step-by-step instructions on how to change
each of them and which to leave alone.
WARNING: There are certain PID settings that if changed can have a negative effect on the opera-
tion of the DD. Damage to the machine or property, personal injury, or negative performance can
be the result, and such damage or difficulties are not covered by the warranty.
PID Display
The digital display on the front panel of the DD normally displays the temperature of the water in the
boiler in real time. You will notice some drift in the temperature as various factors affect the temperature.
Normally, when the machine is idling, that will not be more than about one or momentarily two degrees.
During an extraction, you will notice that the temperature displayed will drop which is a normal occur-
rence. Even though the brew boiler water is preheated before entering the brew boiler, the incoming water is
still slightly cooler than the water already heated in the brew boiler. The temperature that really matters is the
temperature of the water hitting the coffee. Tests with sophisticated equipment have shown that the drift in
temperature at the coffee is within a one degree range. This is a positive result from the design of the DD and
how the water is transported out of the boiler and to the coffee. So don’t be concerned about the change in the
display’s temperature reading when an espresso extraction is taking place.
On and Off
At any time you desire, you can turn the PID on or off. ON is the factory default when the machine is first
powered up. If you turn the PID off, that becomes the default, even if the machine is unplugged. The button
to the right of the PID’s display controls this function. To turn the PID off, when the machine has powered up
and the PID displays the brew-boiler’s temperature, press and hold the PID Power button for approximately
one second until “oFF” is displayed. Repeat to turn the PID’s function back on.
NOTE: When the PID is turned off, the brew boiler’s heating element is no longer energized and
the water in the brew boiler begins to cool.
CAUTION: Only change the temperature settings with the brew boiler on (the PID display should
show the current brew boiler temperature). “oFF” should not be displayed before making changes.
Changing The Measurement System (C or F)
The PID system can be easily changed to display your choice of Centigrade or Fahrenheit units of tem-
perature measurement:
1 With the power switch in “Position 0,” hold down both PID buttons at the same time turn the power switch
to either “Position I” or “Position II.
2 Continue holding the buttons down until the display reads “F.03”.
3 Release the buttons
4 Press the right button to display the current default temperature measurement system which will be either
“°F” or “°C.” Press either button to toggle between “°F” or “°C”. If no button is pressed for a period of ap-
proximately two seconds, the display will revert to “F.03.Pressing the right button will once again display
the last-selected temperature measurement system.
5 To commit the change to the PID’s memory, release the buttons and turn the DD off. Next time you turn
the DD on, the last-selected measurement system will be in use and remain the default until changed by the
user.
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vibiemme Vibiemme Double Domobar version 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vibiemme Vibiemme Double Domobar version 3 in the language / languages: English as an attachment in your email.

The manual is 7,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vibiemme Vibiemme Double Domobar version 3

Vibiemme Vibiemme Double Domobar version 3 Additional guide - English - 3 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info