Battery charger / inverter COMBI-GAMMA
54 090138.02
A1-04: Init Password 1
This constant is reserved for the factory to test and set the functions.•
Users are not allowed to set this constant.•
Lock the constants setting (A1-01=1)
Finish setting all the programmable parameters to the desired values.1.
Change A1-01=0 (Operation only), factory setting is A1-01=1 (Constant set).2.
Go to A1-04 and press RUN/STOP key and UP key at the same time till A1-05 parameter 3.
occurs.
Enter the desired password (max. 4 digits)4.
Press UP key to leave A1-055.
Above procedure completes locking the constants setting and no more programming se-
lection would appear. A1-01 would only display 0 (Operation only) and would not display
1 (Constants set).
Unlock the constants setting
Enter the password in A1-04 to be exactly the same as the one earlier set in A1-051.
When the password in A1-04 matches the one earlier set in A1-05, the unlocking is com-2.
pleted. A1-01=1 (Constants set) would appear again for programming.
B Group (General):
B1 Group (Output Frequency)
B1-01: Output frequency
B1-01 is used to set the output frequency at INVERTER AC output•
Setting Function
B1-01=0
(Initial setting)
50Hz at INVERTER AC output
B1-01=1 60Hz at INVERTER AC output
B2-08: AC IN Frequency Range•
Setting Function
B2-08=0
When B1-01=0: Acceptable AC input frequency is 50Hz ±5Hz (45~55Hz)
When B1-01=1: Acceptable AC input frequency is 60Hz ±5Hz (55~65Hz)
B2-08=1
(Initial setting)
Accept wide AC input frequency range between 45~65Hz
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vetus COMBI1512 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vetus COMBI1512 in the language / languages: English as an attachment in your email.

The manual is 4,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vetus COMBI1512

Vetus COMBI1512 Usermanual and installation guide - Dutch - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info