IMPORTANT: You must attach the four (4) pieces of the
new vinyl siding stando󰀨 to the horizontal termination
cap in specic order to ensure a weather tight t. Loosely
assemble the four parts, in order, around the base of the
horizontal termination cap. Place the rst of four pieces
along the upper edge of the cap, then using two (2) screws
per side, secure each piece to the pre-drilled holes along
both sides of the cap, nally, attach the nal piece to the
bottom edge of the cap. Tighten all screws and mount cap,
with all four (4) pieces attached, directly onto the wall with
the four (4) 2-1/2" (64 mm) screws provided, Figure 3.29.
ST982
simp vinyl sidind
8/07
Cut Back
Siding 4 pc. Vinyl Siding
Stando󰀨
Wood Screws
(4 Req.)
Wood Screw
Figure 3.29
NOTES:
1. The four (4)
wood screws
provided should
be replaced
with appropriate
fasteners for use
on brick, block,
concrete or other
types of sidings.
2. For buildings with
vinyl siding or
stucco, another
component must
be used between
the horizontal
termination cap
and the wall
surface. The vinyl
siding stando󰀨
prevents excessive heat from possibly melting the vinyl
siding material. Vinyl siding stando󰀨s are not required
with snorkels. For vinyl wall installations a 4-piece vinyl
siding stando󰀨 should be assembled and installed
between the horizontal termination cap and the exterior
wall, Figure 3.29. The vinyl should be cut away to the
outer edges of the assembled stando󰀨.
HOT
ST981
SIMP termination
8/07
Wood
Screws
Figure 3.28
Step 6 - Slide the wall thimble cover up to the wall surface
and attach to the wall with screws provided, Figure 3.31.
Apply optional decorative brass trim to wall thimble cover
if desired.
Vertical Installation
Step 1 - Check these installation instructions for required
clearances (air spaces) to combustibles when passing
through ceilings, walls, roofs, enclosures, attic rafters or
other nearby combustible surfaces. Do not pack air spaces
with insulation. Check these instructions for maximum
vertical rise of the venting system and any maximum
horizontal o󰀨set limitations.
Figure 3.30
ST983
wall thimble cover
8/07
Sheet Metal
Screws
Wall Thimble Cover
Zero Clearance
Wall Sleeve
Firestop
3. When penetrating through stucco wall, install the counter
ashing. The counter ashing allows stucco, or other
materials, to be nished directly to the sides of the
termination cap. First attach the counter ashing to the
base of the horizontal termination cap with the small
screws provided, then mount entire assembly onto the wall
with the four (4) 2-1/2" (64 mm) wood screws provided.
Step 4 - Before connecting your horizontal pipe sections to
the horizontal termination cap, slide the wall thimble cover
over the pipe section nearest the interior side of wall, Figure
3.14.
Step 5 - Slide the appliance and vent assembly towards the
wall, carefully inserting the pipe section into the cap assembly.
It is important the pipe section extends into the back of the
termination cap with a minimum overlap of 1-1/4" (32 mm).
Use the two (2) sheet metal screws provided to secure the
pipe section to the back of the termination cap. The wall
thimble cover will cover the screw heads, Figure 3.30.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vermont Castings Intrepid - Gas at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vermont Castings Intrepid - Gas in the language / languages: English as an attachment in your email.

The manual is 17.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info