Vermont Castings • Encore Model 2040-CAT-C Owner’s Manual_R14 • 2019 - ___ • 12/23 188390-204C
Cement
Stove Gasket
Figure 3.5-Layabeadofgasketsiliconeorcementthenpress
gasket in place.
F. The Chimney System
Creosote
Your Encore® Model 2040-CAT-C is designed to reduce
creosote build-up signicantly. However, regular chimney
inspection and maintenance must still be performed. For
safety, good stove performance, and to protect your chimney
and chimney connector, inspect your chimney and chimney
connector on a regular schedule. Clean the system if
necessary. Failure to keep the chimney and connector system
cleancanresultinaseriouschimneyre.
6.Startingatoneend,pressthegasketintothechannel,
Figure3.5.Ensureagoodjointwherethegasketmeets
beforetrimminganyexcess.Donotoverlapthegasket
ends or leave ends with ragged edges.
7.Pressthegasketedpartrmlyagainstitsnormalmating
surface to seat the gasket evenly in its channel. Close
and latch the door to do this, or tap other parts with the
rubbermallet(orhammer/blockofwood).
8.Cleananyexcesscementfromaroundthechannel,then
let the cement that holds the new gasket dry thoroughly.
9.Thestove’sdoorsmayneedadjustmentafteryouhave
regasketedthem. Initially, it may require looseningthe
latchtoaccommodatethenewgasket;afterafewweeks,
it may need tightening to compensate for compression of
the new gasket.
All Gasketed Construction Gaskets
Othergasketsformsealsbetweenallothernon-movingparts,
but these are not subject to the same wear and deterioration
asgasketsonmovingparts.Itisunlikelythatyouwillever
need to replace these gaskets unless the involved parts are
disassembledandthenputbacktogether.Ifthisisthecase,
thejobshouldbedoneonlybyaqualiedservicetechnician.
5/16”diametergasketsealsthefollowingparts:
• Thelowerrebacktothebackpanel
• Theleftandrightairplates(innersides)
All connections between the stove plates.
2. Use a wire brush or the tip of a screwdriver to clean
the channel of any remaining cement or bits of gasket.
Removestubborndepositsofcementwithacoldchisel
ifnecessary,Figure3.4.
3.Determine the correct length of the appropriate-sized
gasketbylayingitoutinthechannel.Allowanextra1-2"
(25-50mm),andmarkthespottobecut.
4.Removethegasketfromthechannel,placeitonawood
cutting surface, and cut it at the marked spot with a utility
knife.
Twist the ends slightly to keep the gasket from unraveling.
5.Layanunbroken1/8"(3mm)beadofsiliconeorcement
inthenewly-cleanedchannel,Figure3.5.
Whenwoodisburnedslowly,itproducestar,organicvapors
and moisture that combine to form creosote. The creosote
vaporscondenseintherelativelycoolchimneyueofaslow-
burningre.Asaresult,creosoteresidueaccumulatesonthe
uelining.Whenignited,thiscreosotemakesanextremely
hotrewithintheuesystemthatcandamagethechimney
andoverheatadjacentcombustiblematerial.Ifasignicant
layerofcreosotehasaccumulated—1/8”(3mm)ormore
—itshouldberemovedtoreducetheriskofachimneyre.
Youcanneverbetoosafe.Contactyourlocalreauthority
forinformationonwhattodointheeventofachimneyre,
and have a clearly understood plan on how to handle one.
Ifyoudoexperienceachimneyre,actpromptlyto:
Close the damper and air control lever.
Get everyone out of the house.
Call the Fire Department.
Inspect the system every two weeks during the heating
season as part of a regular maintenance schedule. To inspect
the chimney, let the stove cool completely. Then, using a
mirrorandastronglight,sightupthroughtheuecollarinto
thechimneyue.Ifyoucannotinspecttheuesysteminthis
fashion, the stove must be disconnected to provide better
viewing access.
Clean the chimney using a brush the same size and shape
astheueliner.Flexibleberglassrodsareusedtorunthe
brush up and down the liner, causing any deposits to fall
to the bottom of the chimney where they can be removed
throughtheclean-outdoor.
Clean the chimney connector by disconnecting the sections,
takingthemoutside,andremovinganydepositswithasti󰀨
wirebrush.Reinstalltheconnectorsectionsaftercleaning,
being sure to secure the joints between individual sections
with sheet metal screws.
Ifyoucannotinspectorcleanthechimneyyourself,contact
yourlocalVermontCastingsdealeroraprofessionalchimney
sweep.
WARNING
!
Inspect and Clean Chimney Frequently Under
certain conditions of use, creosote buildup may occur
rapidly.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vermont Castings Encore at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vermont Castings Encore in the language / languages: English as an attachment in your email.

The manual is 4.61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vermont Castings Encore

Vermont Castings Encore User Manual - French - 46 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info