Andirons Help Protect the Glass
Your stove has andirons to keep logs away from the glass
panels. The andirons are essential to maintain clear re
viewing, and should be left in place. Since the andirons may
slightly hinder refueling through the front doors, most stove
owners will prefer the convenience of top loading through
the griddle. Do not place fuel between the andirons and the
doors.
Burn Only High-Quality Wood
The Dauntless FlexBurn® is designed to burn natural wood
only; do not burn fuels other than that for which it was
designed.
IMPORTANT: Do not burn any type of articial or
synthetic materials such as re starter logs (containing
wax) in this appliance. Never burn liquid-based fuels
such as kerosene, gasoline or alcohol.
Burning any materials not allowed in these instructions, or
over-ringthestove,mayvoidthewarranty.
You’ll enjoy the best results when burning wood that has
been adequately air-dried. The wood should be 16” - 18”
(406-457 mm) in length.Avoid burning “green” wood that
hasnotbeenproperlyseasoned.(Note: Properly seasoned
rewoodhasamoisturecontentbelow20percent.)Donot
burn construction materials; they often contain chemicals
and metals that can damage the inside surfaces of the
stove and pollute the air. Do not burn ocean driftwood; when
it burns, the salt it contains will attack the cast iron.
The best hardwood fuels include oak, maple, beech, ash,
and hickory that has been split, stacked, and air-dried
outside under cover for at least one year.
Ifhardwoodis notavailable,youcanburn softwoodsthat
include tamarack, yellow pine, white pine, Eastern red cedar,
r,andredwood.Theseshouldalsobeproperlydried.
Storesplitwoodundercovertokeepitdry.Evenforshort-
term storage, be sure to keep wood a safe distance from the
stove and keep it out of the areas around the stove used for
refueling and ash removal.
Surface Thermometer is a Valuable Guide to Operation
An optional surface thermometer tells you when to adjust
the air control, and when to refuel, Figure 2.7.
Figure 2.7-Taketemperaturereadingswithathermometerlocated
in the middle of the griddle.
For example, when the thermometer registers at least
450°F(230°C)onthestovetopafterstart-upyouknowthe
stove is hot enough and it may be time to close the damper
ifasu󰀩cientemberbedhasalsobeenestablished.Note
that the stove will warm up much sooner than the chimney,
though;awarmchimneyisthekeytoeasy,e󰀨ectivestove
operation. When thermometer readings drop below 350°F.
(175°C)it’stimetoadjusttheaircontrolforahigherburn
rate or to reload the stove. A temperature reading over
650°F.(340°C)isasigntoreducetheairsupplytoslowthe
burn rate.
Use the following temperature ranges as a guide:
• Readingsinthe350°-500°F.(175°-260°C)rangeindicate
low to medium heat output.
• 500°-600°F. (260°-315°C) readings indicate medium
heat output.
• Readingsof600°-650°F.(315-340°C)indicatehighheat
output.OperatingyourDauntlessFlexBurn® continuously
atgriddletemperatureshigherthan650°F(340°C)may
damagethecastironorenamelnish.
Use the Air Control Settings that Work Best for You
No single air control setting will t every situation. Each
installation will di󰀨er depending on the quality of the fuel,
theamountofheatdesired,andhowlongyouwishthere
to burn; outdoor air temperature and pressure also a󰀨ect
draft.
The control setting also depends on your particular
installation’s “draft,” or the force that moves air from the
stove up through the chimney. Draft is a󰀨ected by such
things as the length, type, and location of the chimney, local
geography, nearby obstructions, and other factors.
Too much draft may cause excessive temperatures in the
Dauntless FlexBurn®, and could even damage the stove.
Ontheotherhand,toolittledraftcancausebackpu󰀩nginto
theroomand/orthe“plugging”ofthechimney.
Howdoyouknowifyourdraftisexcessivelyhighorlow?
Symptoms of too much draft include an uncontrollable
burn or a glowing-red stove part. Signs of weak draft are
smoke leaking into the room through the stove or chimney
connector joints or low heat output.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vermont Castings Dauntless FlexBurn at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vermont Castings Dauntless FlexBurn in the language / languages: English as an attachment in your email.

The manual is 8.21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vermont Castings Dauntless FlexBurn

Vermont Castings Dauntless FlexBurn User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info