9. Technische specificaties
This device is not calibrated when purchased!
Regulations concerning environment of use:
Use this meter only for measurements in CATI, CATII, CAT III (<1000V) and CAT
IV (<600V) environments (see §4)
Use this meter only in a pollution degree 2 environment (see §5)
Ideal working conditions include:
Temperature: 18 to 28°C (64°F to 82°F)
relative humidity: max. 75%
altitude: max. 2000m (6560ft)
9.1. General
Max. Voltage
600V CAT IV, 1000V CAT III
Display
3
5/6-
digit LCD, 2 to 3 samples/sec.
Fuse Protection
µA/mA-range: 630mA/1000V (Ø10.3x38mm)
10A-range: 10A/1000V (Ø10.3x38mm)
Temperature coefficient
0.1x(specified accuracy)/°C (<18°C or >28°C)
Power Supply
9V NEDA 1604 6F22 006P (incl.)
Ranging Method
manual/automatic
Polarity Indication
" - " is displayed
Overrange Indication
"OL" is displayed automatically
Battery-Low Indication
" " is displayed
Operating Temperature
0°C to 40°C (32~122°F) (<80%RH, <10°C non
condensing)
Storage Temperature
-10°C to 60°C (14~140°F) (<70%RH, battery removed)
Dimensions
190x90x40mm
Weight
±500g (incl. battery)
9.2. DC Voltage
Range
Resolution
Accuracy
600mV
100µV
(0.5% of rdg + 5 digits)
6V
1mV
(0.8% of rdg + 5 digits)
60V
10mV
600V
100mV
1000V
1V
(1.0% of rdg +2 digits)
Input Impedance: >10M for all ranges
9.3. AC Voltage
Range
Resolution
Accuracy
600mV
100µV
(1.0% of rdg + 5 digits)
6V
1mV
60V
10mV
600V
100mV
1000V
1V
(1.5% of rdg +2 digits)
Input Impedance: >10M for all ranges
Frequency Range: 40 to 400Hz
Overload protection: 1000Vdc or ac rms.
9.4. DC Current
Range
Resolution
Accuracy
600µA
0.1µA
(1.5% of rdg + 3 digits)
6mA
1µA
60mA
10µA
600mA
0.1mA
6A
1mA
(1.5% of rdg +5 digits)
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Velleman DVM4100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Velleman DVM4100 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 1,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info